ROCKAWAY BEACH, NY —
OSHA Inspection: J. HOYLER CONSTRUCTION, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of J. HOYLER CONSTRUCTION, INC. in 97- 20 ROCKAWAY BEACH BLVD., ROCKAWAY BEACH, NY 11693 (NAICS 238320). OSHA activity number 343182143.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J. HOYLER CONSTRUCTION, INC.
- Site address
- 97- 20 ROCKAWAY BEACH BLVD.
- City
- ROCKAWAY BEACH
- State
- NY
- ZIP
- 11693
- Mailing
- 7 E. 7TH RD., FAR ROCKAWAY, NY 11693
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Oct 18, 2018
- Abate by
- Oct 24, 2018
- Penalty
- Initial $3,880 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) (a) At the worksite - An employee painting building from a tubular welded scaffold was standing on a single plank approximately 18 feet above a concrete sidewalk; on or about 05/24/18. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
- — F (O) $1600
- — C (S) $3880
- — Z (S) $3880
1926.454 A
- Issued
- Oct 18, 2018
- Abate by
- Nov 6, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) At the worksite - An employee painting building from a tubular welded scaffold was standing on a single plank approximately 18 feet above a concrete sidewalk and there was no access ladder or fall protection; on or about 05/24/18. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Oct 18, 2018
- Abate by
- Oct 24, 2018
- Penalty
- Initial $2,772 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. (a) At the worksite - Employees working from a tubular welded scaffold used the scaffold frame to access the working levels. No ladder was provided; on or about 05/24/18.
Recent events (3)
- — F (O) $1600
- — C (S) $2772
- — Z (S) $2772
1926.451 G01 VII
- Issued
- Oct 18, 2018
- Abate by
- Oct 24, 2018
- Penalty
- Initial $3,880 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. (a) At the worksite - An employee painting a building from a tubular welded scaffold approximately 18 feet above a concrete sidewalk was not protected from falling; on or about 05/24/18. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
- — F (O) $1600
- — C (S) $3880
- — Z (S) $3880
More inspections in this industry (NAICS 238320)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343182143.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.