Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UA GALICIA CONSTRUCTION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UA GALICIA CONSTRUCTION INC. in 5293 STALLION COURT, LIBERTY TOWNSHIP, OH 45044 (NAICS 238130). OSHA activity number 343183067.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch UA Galicia Construction INC. — free Get an email when a new federal OSHA severe-injury report for UA Galicia Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
5293 STALLION COURT
City
LIBERTY TOWNSHIP
State
OH
ZIP
45044
Mailing
1100 SNIDER RD #51, MASON, OH 45040
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 16, 2018
Abate by
Nov 9, 2018
Penalty
Initial $4,268 · Current $4,268
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  On May 24, 2018, there were no frequent and regular inspections being performed by a competent person in that employees were performing framing work at fall heights greater than 11 feet above the concrete surface below without a fall protection system; one employee and the owner were observed using rope and straps to hoist a preassembled gable, while standing on a top plate, onto the roof structure while not utilizing a fall protection system; and two portable ladders being used by employees for roof access did not extend 3 feet above the upper landing surface.
Recent events (1)
  • — Z (S) $4268

1926.503 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 16, 2018
Abate by
Nov 9, 2018
Penalty
Initial $4,268 · Current $4,268
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.   The employer did not provide a training program for employees that were observed performing framing work on a residential roof structure while not utilizing a fall protection system and exposed to fall heights greater than 11 feet above the concrete surface below.
Recent events (1)
  • — Z (S) $4268

1926.501 B13

Repeat Gravity 10 1 instance 3 exposed
Issued
Oct 16, 2018
Abate by
Nov 9, 2018
Penalty
Initial $8,536 · Current $8,536
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  On May 24, 2018, located on a residential roof structure, employees were observed performing framing work while not utilizing a fall protection system. Potential fall heights were measured to be greater than 11 feet above the concrete surface below.  UA Galacia Construction Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1279422, citation number 1, item number 1 and was affirmed as a final order on 1/30/2018, with respect to a workplace located at 10119 Arnold Dr., Cincinnati OH 45215.
Recent events (1)
  • — Z (R) $8536

View UA Galicia Construction INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343183067.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.