Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PGT INDUSTRIES INC./CGI WINDOWS AND DOORS INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PGT INDUSTRIES INC./CGI WINDOWS AND DOORS INC. in 3780 WEST 104TH ST, HIALEAH, FL 33018 (NAICS 332321). OSHA activity number 343184420.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PGT Industries Inc./Cgi Windows and Doors INC. — free Get an email when a new federal OSHA severe-injury report for PGT Industries Inc./Cgi Windows and Doors INC. is published. One employer, no account, unsubscribe in one click.
Site address
3780 WEST 104TH ST
City
HIALEAH
State
FL
ZIP
33018
Mailing
3780 WEST 104TH ST., HIALEAH, FL 33018
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332321
Employees
350
Ownership type
A

4 citations on file for this inspection.

1910.95 I05

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 15, 2018
Penalty
Initial $10,163 · Current $10,163
29 CFR 1910.95(i)(5): The employer did not ensure proper initial fitting and supervise the correct use of all hearing protectors:  On or about July 24, 2018, at 3780 West 104th ST. Hialeah, FL 33018 windows department, an employee operating a cutting saw was exposed to a noise level of 90.7dBA, which exceeds the action level of 83.4dBA, during the 10-hr representative sampling period. The employer failed to ensure the trainee working alongside this employee was wearing hearing protection properly.
Recent events (3)
  • — R (S) $10163
  • — C (S) $10163
  • — Z (S) $10163

1910.101 B

Serious Gravity 5 2 instances 3 exposed
Issued
Nov 15, 2018
Penalty
Initial $12,195 · Current $12,195
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:   a) On or about May 23, 2018, at the 3780 West 104th St. Hialeah, FL 33018 welding department, three (3) argon cylinders were stored and not secured, creating a struck-by hazard to the employees.   b) On or about May 23, 2018, at the 3780 West 104th St. Hialeah, FL 33018 maintenance department, an argon cylinder was stored and not secured, creating a struck-by hazard to the employees.  c) On or about May 22, 2018, at the 3780 West 104th St. Hialeah, FL 33018 maintenance department, an acetylene and oxygen cylinder were stored and not secured, creating a struck-by hazard to the employees.
Recent events (3)
  • — R (S) $12195
  • — C (S) $12195
  • — Z (S) $12195

1910.252 C01 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 15, 2018
Abate by
Jan 4, 2019
Penalty
Initial $6,097 · Current $6,097
29 CFR 1910.252(c)(1)(iv): The employer did not include the potentially hazardous materials employed in fluxes, coatings, coverings, and filler metals, all of which are potentially used in welding and cutting, in the program established to comply with Hazard Communication Standard (HCS) (sec. 1910.1200).  On or about May 22, 2018, at the 3780 West 104th St. Hialeah, FL 33018 facility, employees were not trained nor did they know where to access the safety data sheets for materials used during welding operations.
Recent events (3)
  • — R (S) $6097
  • — C (S) $6097
  • — Z (S) $6097

1910.253 B04 I

Other-than-serious 1 instance 1 exposed
Issued
Nov 15, 2018
Penalty
Initial $0 · Current $0
1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:  On or about May 22, 2018 at the 3780 West 104th St. Hialeah, FL 33018 maintenance department , an oxygen cylinder was stored next to an acetylene cylinder, exposing employees to a fire hazard.
Recent events (3)
  • — R (O) $0
  • — C (O) $0
  • — Z (O) $0

View PGT Industries Inc./Cgi Windows and Doors INC.'s full OSHA safety record →