Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUALITY SIDING & REMODELING, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of QUALITY SIDING & REMODELING, INC in 260 MAIN ST, SPENCER, MA 01562 (NAICS 238160). OSHA activity number 343186391.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Siding & Remodeling, INC — free Get an email when a new federal OSHA severe-injury report for Quality Siding & Remodeling, INC is published. One employer, no account, unsubscribe in one click.
Site address
260 MAIN ST
City
SPENCER
State
MA
ZIP
01562
Mailing
15 A WOODLAND RD, MILFORD, MA 01757
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

9 citations on file for this inspection.

1903.19 C01

Other-than-serious 7 instances 5 exposed
Issued
Oct 31, 2018
Abate by
Nov 13, 2018
Penalty
Initial $311 · Current $311
29 CFR 1903.19(c)(1): The Employer did not certify to OSHA (the Agency) that each cited violation has been abated within 10 calendar days after the abatement date:  As of October 29, 2018, the employer had not certified to OSHA that the abatement was completed for the violations from Inspection 1318639, issued on 7/31/18 with a final order date of 8/27/18
Recent events (1)
  • — Z (O) $311

1903.19 D01

Other-than-serious 7 instances 5 exposed
Issued
Oct 31, 2018
Abate by
Nov 13, 2018
Penalty
Initial $311 · Current $311
29 CFR 1903.19(d)(1):The employer did not submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:  As of October 29, 2018, the employer had not submitted to the Agency the abatement certification required for the serious violations issues on 7/31/18, which it was indicated that such abatement documentation was required to be submitted to the Agency.
Recent events (1)
  • — Z (O) $311

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 31, 2018
Abate by
Aug 6, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was protected by guardrail systems, safety net system, or personal fall arrest system:  a) 260 Main St., Spencer, MA: On or about May 23, 2018, 3 employees were observed roofing this residence, more than 17 feet above the ground below without any fall protection.   Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (1)
  • — Z (S) $3880

1926.502 D15

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 31, 2018
Abate by
Aug 6, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached:  a) 260 Main St., Spencer, MA: On or about May 23, 2018, an employee was observed roofing this residence while attached to a roof anchor that was not installed correctly, and thus not capable of supporting at least a 5,000 pound load.    Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (1)
  • — Z (S) $3880

1926.502 D17

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 31, 2018
Abate by
Aug 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(17): The attachment point of the body belt was not located in the center of the wearer's back:  a) 260 Main St., Spencer, MA: On or about May 23, 2018, an employee was observed roofing this residence, with his attachment point at his waist.    Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 31, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access:  a) 260 Main St., Spencer, MA: On or about May 23, 2018, a employee was observed accessing the roof top work location by using an aluminum extension ladder that did not extend 3 feet past the upper landing surface.   Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (1)
  • — Z (S) $3880

1926.1053 B05 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 31, 2018
Abate by
Aug 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).  a) 260 Main St., Spencer, MA: On or about May 23, 2018, a employee was observed accessing the roof top work location by using an aluminum extension ladder that was not set at the angle proscribed above.    Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (1)
  • — Z (S) $0

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 31, 2018
Abate by
Aug 6, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.1053(b)(4): Ladders were not used only for the purpose for which they were designed.  a) 260 Main St., Spencer, MA: On or about May 23, 2018, a employee was observed accessing the roof top work location by climbing the rails of the shingle lift system at the job site.
Recent events (1)
  • — Z (S) $2772

1926.150 C01 VI

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 31, 2018
Abate by
Aug 6, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite.  a) 260 Main St., Spencer, MA: On or about May 23, 2018, there was no fire extinguisher at this job site where more than 5 gallons of gasoline was on site to fuel the generator and other equipment.
Recent events (1)
  • — Z (S) $2772

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343186391.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.