AVENEL, NJ —
OSHA Inspection: AP CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AP CONSTRUCTION INC. in 33 RANDOLPH AVE., AVENEL, NJ 07001 (NAICS 238160). OSHA activity number 343188066.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AP CONSTRUCTION INC.
- Site address
- 33 RANDOLPH AVE.
- City
- AVENEL
- State
- NJ
- ZIP
- 07001
- Mailing
- 1263 59TH STREET, BROOKLYN, NY 11219
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B10
- Issued
- Jun 18, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a) Employee(s) performed flashing repairs, working at the west edge of a flat roof at 33 Randolph Avenue in Avenel NJ without any means of fall protection; exposed to fall hazard of 20 ft. Condition(s) were noted on or about 5/24/2018.
Recent events (1)
- — Z (S) $3880
1926.1053 B01
- Issued
- Jun 18, 2018
- Penalty
- Initial $2,772 · Current $2,772
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Employee(s) were repairing roof flashing on the west side roof of a commercial building at 33 Randolph Avenue in Avenel NJ. The extension ladder used for access to the roof was not extended at least 3 feet past the eave; exposing employee(s) to a fall of 20ft. The conditions were noted on or about 5/24/2018.
Recent events (1)
- — Z (S) $2772
1926.1053 B15
- Issued
- Jun 18, 2018
- Penalty
- Initial $2,772 · Current $2,772
General-duty citation text
29 CFR 1926.1053(b)(15): Ladder(s) were not inspected by a competent person for visible defects on a periodic basis and/or after an occurrence that could have affected their safe use: a) Employee(s) were repairing roof flashing on the west side roof of a commercial building at 33 Randolph Avenue in Avenel NJ. The extension ladder used for roof access / egress was not subject to periodic inspection by a competent person, and featured an inwardly bent foot that could impact the ladder stability; exposing employee(s) to a fall of 20ft. The conditions were noted on or about 5/24/2018.
Recent events (1)
- — Z (S) $2772
1926.1053 B16
- Issued
- Jun 18, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired. a) Employee(s) were repairing roof flashing on the west side roof of a commercial building at 33 Randolph Avenue in Avenel NJ. The extension ladder used for roof access / egress was not subject to periodic inspection by a competent person, and featured an inwardly bent foot that could impact the ladder stability; exposing employee(s) to a fall of 20ft. The conditions were noted on or about 5/24/2018.
Recent events (1)
- — Z (S) $0
More inspections at AP Construction INC.
View AP Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343188066.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.