FLEMINGTON, NJ ·
OSHA Inspection: EDJ DEVELOPMENT LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EDJ DEVELOPMENT LLC in 61 BONNELL ST, FLEMINGTON, NJ 08822 (NAICS 238170). OSHA activity number 343190393.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EDJ DEVELOPMENT LLC
- Site address
- 61 BONNELL ST
- City
- FLEMINGTON
- State
- NJ
- ZIP
- 08822
- Mailing
- 28 OLD CLINTON RD, FLEMINGTON, NJ 08822
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.451 C02
- Issued
- Jun 14, 2018
- Penalty
- Initial $2,772 · Current $1,802 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: A) Bonnell St Flemington, NJ 08822 Scaffold poles used to erect pump jack scaffold were set in mud with no mud sills and or base plates. Occurred on or about 05/30/18
Recent events (2)
- · I (S) $1802
- · Z (S) $2772
1926.451 G04 I
- Issued
- Jun 14, 2018
- Penalty
- Initial $3,880 · Current $2,522 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along open sides and ends of platforms: A) 61 Bonnell St Flemington, NJ 08822 Employees were working on a pump jack scaffold platform that was missing mid-rail and end rail. Occurred on or about 05/30/18
Recent events (2)
- · I (S) $2522
- · Z (S) $3880
1926.452 J02
- Issued
- Jun 14, 2018
- Penalty
- Initial $2,772 · Current $1,802 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles of pump jack scaffold(s) were not secured to the structure by rigid triangular bracing, or equivalent, at the bottom: A) 61 Bonnell St Flemington, NJ 08822 The poles of the pump jack scaffold were not secured at the bottom, to prevent displacement of support poles. Occurred on or about 05/30/18
Recent events (2)
- · I (S) $1802
- · Z (S) $2772
More inspections in this industry (NAICS 238170)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343190393.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.