ROYERSFORD, PA —
OSHA Inspection: PENNSYLVANIA INSERT CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PENNSYLVANIA INSERT CORP. in 490 1ST AVE., ROYERSFORD, PA 19468 (NAICS 332999). OSHA activity number 343190914.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PENNSYLVANIA INSERT CORP.
- Site address
- 490 1ST AVE.
- City
- ROYERSFORD
- State
- PA
- ZIP
- 19468
- Mailing
- 490 1ST AVE., ROYERSFORD, PA 19468
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 24
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.217 B04 I
- Issued
- Aug 30, 2018
- Penalty
- Initial $3,696 · Current $2,587 Reduced
General-duty citation text
29 CFR 1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals: a) Rousselle Brand, Model 3E Mechanical Power Press - On or about April 12, 2018, employees were using a full revolution mechanical power press with a pedal that was not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals.
Recent events (2)
- — I (S) $2587.2
- — Z (S) $3696
1910.217 C01 I
- Issued
- Aug 30, 2018
- Abate by
- Sep 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es). a) Rousselle Brand, Model 3E Mechanical Power Press - On or about April 12, 2018, employees were using a full revolution mechanical power press without the availability of point of operation guards or devices sufficient to prevent employees hands from entering into the point of operation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 D09 I
- Issued
- Aug 30, 2018
- Abate by
- Oct 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(d)(9)(i): The employer did not establish a die setting procedure for mechanical power press(es) that would ensure compliance with 29 CFR 1910.217(c) a) Rousselle Brand, Model 3E Mechanical Power Press - On or about April 12, 2018, the employer had not established die setting procedures that would protect employees from point of operation injuries.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 E01 I
- Issued
- Aug 30, 2018
- Abate by
- Oct 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: a) Rousselle Brand, Model 3E Mechanical Power Press - On or about April 12, 2018, the employer had not established a program of periodic and regular inspections to insure that the equipment were in a safe operating condition and adjustment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- Aug 30, 2018
- Abate by
- Sep 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. a) Foyer entrance area - On or about May 30, 2018, a red colored ITE Imperial Corporation switchgear box had an unused knock out type opening that were not effectively closed. b) Foyer entrance area - On or about May 30, 2018, an aqua colored Jefferson Electric brand, Powerformer transformer box had an unused knock out type opening that were not effectively closed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Pennsylvania Insert Corp.
View Pennsylvania Insert Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343190914.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.