CHANDLER, AZ —
OSHA Inspection: CLASSY CLOSETS ETC., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CLASSY CLOSETS ETC., INC. in 1251 S NELSON DR, CHANDLER, AZ 85226 (NAICS 337110). OSHA activity number 343194536.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLASSY CLOSETS ETC., INC.
- Site address
- 1251 S NELSON DR
- City
- CHANDLER
- State
- AZ
- ZIP
- 85226
- Mailing
- 1251 S NELSON DR, CHANDLER, AZ 85226
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 120
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.151 C
- Issued
- Sep 28, 2018
- Abate by
- Oct 11, 2018
- Penalty
- Initial $9,977 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Granite Room - Employees were exposed to injurious corrosive materials, and suitable facilities for quick drenching or flushing of eyes and body were not provided within the work area for immediate use. Employees working with Acetone, had to travel through several rooms to access the eyewash area in the restrooms. Female restroom was locked and required a key to enter.
Recent events (2)
- — I (S) $4000
- — Z (S) $9977
1910.212 A01
- Issued
- Sep 28, 2018
- Abate by
- Oct 11, 2018
- Penalty
- Initial $6,652 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Workshop - Machine guarding was not provided on the Sears Craftsman drill press to protect employees from an entanglement hazard created by the rotating chuck and bit when employees are operating the drill press. b) Workshop - Machine guarding was not provided on the Chicago Power Tools drill press to protect employees from an entanglement hazard created by the rotating chuck and bit when employees are operating the drill press.
Recent events (2)
- — I (S) $6000
- — Z (S) $6652
1910.215 B09
- Issued
- Sep 28, 2018
- Abate by
- Oct 11, 2018
- Penalty
- Initial $6,652 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Workshop - The distance between the abrasive wheel and the top of the safety guard peripheral member exceeded one fourth inch as the tongue guard was missing.
Recent events (2)
- — I (S) $4000
- — Z (S) $6652
1910.305 G01 IV A
- Issued
- Sep 28, 2018
- Abate by
- Oct 11, 2018
- Penalty
- Initial $6,652 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: The employer did not ensure that flexible cables were not used as a substitute for the fixed wiring of a structure exposing employees to electrical hazards in the following instances: a) Paint Area - An extension cord was secured to the wall to provide power to a light fixture in a wood constructed paint booth. b) Specialty Shop Area - An extension cord was permanently mounted and routed through a cabinet to provide power to a microwave oven.
Recent events (2)
- — I (S) $1000
- — Z (S) $6652
More inspections at Classy Closets ETC., INC.
View Classy Closets ETC., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343194536.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.