Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCHULZ XTRUDED PRODUCTS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SCHULZ XTRUDED PRODUCTS in 1001 SCHULZ BLVD., ROBINSONVILLE, MS 38664 (NAICS 331210). OSHA activity number 343197232.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schulz Xtruded Products — free Get an email when a new federal OSHA severe-injury report for Schulz Xtruded Products is published. One employer, no account, unsubscribe in one click.
Site address
1001 SCHULZ BLVD.
City
ROBINSONVILLE
State
MS
ZIP
38664
Mailing
1001 SCHULZ BLVD., ROBINSONVILLE, MS 38664
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
140
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 2, 2018
Abate by
Jul 25, 2018
Penalty
Initial $7,633 · Current $4,580 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  (a) ID Blaster and Staging Rack - On or about May 30, 2018 the employer did not develop a energy control procedure for the cleaning of shot material around the machinery.
Recent events (2)
  • — I (S) $4579.8
  • — Z (S) $7633

1910.147 D04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 2, 2018
Abate by
Jul 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.  (a) ID Blaster and Staging Rack - On or about May 30, 2018 operators do not lockout the machinery before entering the area to clean.