BUFFALO, NY —
OSHA Inspection: SALIT SPECIALTY REBAR
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SALIT SPECIALTY REBAR in 1050 MILITARY ROAD, BUFFALO, NY 14217 (NAICS 332312). OSHA activity number 343199626.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SALIT SPECIALTY REBAR
- Site address
- 1050 MILITARY ROAD
- City
- BUFFALO
- State
- NY
- ZIP
- 14217
- Mailing
- 1050 MILITARY ROAD, BUFFALO, NY 14217
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 18
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 5, 2018
- Abate by
- Jul 27, 2018
- Penalty
- Initial $5,174 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by pinch points created during machine operation: a) On or about 05/22/2018 in the bending area; where employees were exposed to pinch points on the R.M.S. Rebar Bender (Serial No. 11-M-557) between the rebar being bent and the fixed points on the machine. ABATEMENT DOCUMENTATION REQUIRED
Recent events (3)
- — J (S) $2500
- — C (S) $5174
- — Z (S) $5174
1910.147 C04 II C
- Issued
- Jul 5, 2018
- Abate by
- Jul 27, 2018
- Penalty
- Initial $3,696 · Current $1,600 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: a) On or about 06/19/18 throughout establishment; where the energy control procedures did not include procedures for removal of the lockout device by someone other than the employee who applied the device. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $1600
- — C (S) $3696
- — Z (S) $3696
1910.147 C06 I
- Issued
- Jul 5, 2018
- Abate by
- Jul 27, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) On or about 06/19/2018; where the energy control procedures which were developed and placed in service on 03/2017 were not reviewed at least annually. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C06 I C
- Issued
- Jul 5, 2018
- Abate by
- Jul 27, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: a) On or about 06/19/2018; where employees regularly perform servicing and maintenance procedures requiring hazardous energy control (lockout), the authorized employees were not evaluated, at least annually, while performing a lockout procedure. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.178 L01 II
- Issued
- Jul 5, 2018
- Abate by
- Jul 27, 2018
- Penalty
- Initial $2,956 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial vehicle: a) On or about 06/19/2018 in the production area; where employees hired between the 08/15/2017 (the date of the most recent powered industrial vehicle training/evaluation/certification) and 06/19/2018, operated powered industrial vehicles without being trained/evaluated and certified. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $1400
- — C (S) $2956
- — Z (S) $2956
More inspections in this industry (NAICS 332312)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343199626.