DALTON GARDENS, ID —
OSHA Inspection: IRONMAN SAFE COMPANY, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of IRONMAN SAFE COMPANY, LLC in 7695 AQUA CIRCLE, DALTON GARDENS, ID 83815 (NAICS 332999). OSHA activity number 343200457.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IRONMAN SAFE COMPANY, LLC
- Site address
- 7695 AQUA CIRCLE
- City
- DALTON GARDENS
- State
- ID
- ZIP
- 83815
- Mailing
- 7695 AQUA CIRCLE, DALTON GARDENS, ID 83815
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 C01
- Issued
- Jul 20, 2018
- Abate by
- Aug 15, 2018
- Penalty
- Initial $2,772 · Current $2,772
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Power Coat Area: On or about May 31, 2018 and at times prior, an employee was wearing a Gerson 9300 respirator while applying Cardinal T013-BK6 powder coating to safes. Note: Abatement certification is required for this item.
Recent events (1)
- — Z (S) $2772
1910.134 E01
- Issued
- Jul 20, 2018
- Abate by
- Aug 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Power Coat Area: On or about May 31, 2018 and at times prior, an employee was wearing a Gerson 9300 respirator while applying Cardinal T013-BK6 powder coating to safes. The employee had not received a medical evaluation. Note: The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. Note: Abatement certification is required for this item.
Recent events (1)
- — Z (S) $0
1910.134 F01
- Issued
- Jul 20, 2018
- Abate by
- Aug 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) Power Coat Area: On or about May 31, 2018 and at times prior, an employee was wearing a Gerson 9300 respirator while applying Cardinal T013-BK6 powder coating to safes. The employee had not received a fit test. Note: Abatement certification is required for this item.
Recent events (1)
- — Z (S) $0
1910.134 G01 I
- Issued
- Jul 20, 2018
- Abate by
- Aug 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i): The employer permitted respirators with tight fitting facepieces to be worn by employees who have facial hair that comes between the sealing surface of the facepiece and the face: (a) Power Coat Area: On or about May 31, 2018 and at times prior, an employee was wearing a Gerson 9300 respirator while applying Cardinal T013-BK6 powder coating to safes. The employee had a beard while wearing the respirator. Note: Abatement certification is required for this item.
Recent events (1)
- — Z (S) $0
1910.134 H02 I
- Issued
- Jul 20, 2018
- Abate by
- Aug 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: (a) Power Coat Area: On or about May 31, 2018 and at times prior, an employee was wearing a Gerson 9300 respirator while applying Cardinal T013-BK6 powder coating to safes. The respirators were being stored out in the open in the powder coat area. Note: Abatement certification is required for this item.
Recent events (1)
- — Z (S) $0
1910.134 K
- Issued
- Jul 20, 2018
- Abate by
- Aug 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: (a) Power Coat Area: On or about May 31, 2018 and at times prior, an employee was wearing a Gerson 9300 respirator while applying Cardinal T013-BK6 powder coating to safes. The employee was not trained to use a respirator. Note: Abatement certification is required for this item.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 332999)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343200457.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.