Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENCOR INDUSTRIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GENCOR INDUSTRIES, INC. in 5201 N. ORANGE BLOSSOM TRAIL, ORLANDO, FL 32810 (NAICS 333120). OSHA activity number 343200614.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gencor Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Gencor Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5201 N. ORANGE BLOSSOM TRAIL
City
ORLANDO
State
FL
ZIP
32810
Mailing
5201 N. ORANGE BLOSSOM TRAIL, ORLANDO, FL 32810
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333120
Employees
300
Ownership type
A

3 citations on file for this inspection.

1910.252 B02 III

Serious Gravity 5 1 instance 105 exposed
Issued
Jun 28, 2018
Abate by
Jul 25, 2018
Penalty
Initial $11,086 · Current $6,652 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  a) In the welding areas, noncombustible or flameproof screens or shields were not used to protect employees from rays produced from welding. This violation was observed on or about May 29, 2018.
Recent events (2)
  • — I (S) $6651.6
  • — Z (S) $11086

1910.334 A02 I

Other-than-serious 2 instances 25 exposed
Issued
Jun 28, 2018
Penalty
Initial $881 · Current $529 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a) In the welding areas of Building 2, an extension cord was not inspected before use and was missing a grounding prong. This violation was observed on or about May 29, 2018.  b) In the welding areas of Building 2, an extension cord was not inspected before use and was missing a grounding prong. This violation was observed on or about May 29, 2018.
Recent events (2)
  • — I (O) $528.6
  • — Z (O) $881

1910.334 A03 I

Other-than-serious 2 instances 25 exposed
Issued
Jun 28, 2018
Penalty
Initial $881 · Current $529 Reduced
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor:  a) In the welding areas of Building 2, an extension cord was not inspected before use and was missing a grounding prong. This violation was observed on or about May 29, 2018.  b) In the welding areas of Building 2, an extension cord was not inspected before use and was missing a grounding prong. This violation was observed on or about May 29, 2018.
Recent events (2)
  • — I (O) $528.6
  • — Z (O) $881

View Gencor Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343200614.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.