OSHA Inspection: ALLIED DECORATION CO., INC. DBA ALLIED SIGN CO.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ALLIED DECORATION CO., INC. DBA ALLIED SIGN CO. in 720 ERIE BLVD WEST, SYRACUSE, NY 13204 (NAICS 339950). OSHA activity number 343200903.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Allied Decoration CO., INC. DBA Allied Sign CO. — free Get an email when a new federal OSHA severe-injury report for Allied Decoration CO., INC. DBA Allied Sign CO. is published. One employer, no account, unsubscribe in one click.
Site address
720 ERIE BLVD WEST
City
SYRACUSE
State
NY
ZIP
13204
Mailing
720 ERIE BLVD WEST, SYRACUSE, NY 13204
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
10
Ownership type
A

5 citations on file for this inspection.

1910.107 E06 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 20, 2018
Penalty
Initial $1,201 · Current $781 Reduced
29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken:    a)  Spray Booth Area, on or about 6/8/18: AllPro Lacquer Thinner was being used  without grounding the 5 gallon container.
Recent events (2)
  • — I (S) $780.65
  • — Z (S) $1201

1910.213 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 20, 2018
Abate by
Aug 10, 2018
Penalty
Initial $1,885 · Current $1,225 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    a)  Plastic Shop, on or about 6/8/18: Delta Table Saw was not guarded by an automatic adjusting hood that completely enclosed the portion of the saw blade above the table and above the material being cut.
Recent events (2)
  • — I (S) $1225.25
  • — Z (S) $1885

1910.213 H01

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 20, 2018
Abate by
Aug 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut:     a)  Saw Bench, on or about 6/8/18:  DeWalt Radial Arm Saw had no lower blade guards on either side of the blade.    b)  Saw Bench, on or about 6/18/18: Skil Radial Arm Saw Model No. 450 had no lower blade guards on either side of blade.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 H04

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 20, 2018
Abate by
Aug 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator:    a) Saw Bench, on or about 6/8/18:  DeWalt Radial Arm Saw did not return to the starting position when released.    b) Saw Bench, on or about 6/8/18:  Skil Radial Arm Saw Model No. 450 did not return to the starting position when released
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 20, 2018
Penalty
Initial $1,201 · Current $781 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:    a) Upper Shop, on or about 6/8/18: A 120 volt breaker panel box had two blanks missing.