OSHA Inspection: ED PIERCE MASONRY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ED PIERCE MASONRY, INC. in 1812 N. LAKEWOOD DR., COEUR D ALENE, ID 83814 (NAICS 238140). OSHA activity number 343201224.

Watch ED Pierce Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for ED Pierce Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1812 N. LAKEWOOD DR.
City
COEUR D ALENE
State
ID
ZIP
83814
Mailing
54 SKY HAWK DR., SPIRIT LAKE, ID 83869
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2200.00 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  (a) 1812 N. Lakewood Dr.: On or about May 22, 2018 and at times prior, at approximately 15 ft. employees were moving materials onto a scaffold that had the cross member removed.  Note: Abatement documentation and certification is required for this item.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $3880

1926.451 G04 XV

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(4)(xv): Cross bracing used in place of a mid rail was unacceptable because the crossing point of two braces was not between 20 inches (0.5 m) and 30 inches ((0.8 M) above the work platform or as a top rail crossing point of two braces were not between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform.    (a) 1812 N. Lakewood Dr.: On or about May 30, 2018 and at times prior, at approximately 30 ft. employees were working on a scaffold with sections that did not have a top rail.  The 30 inch cross member met the height of a mid-rail, but it did not have a top rail.   (b) 1812 N. Lakewood Dr.: On or about May 30, 2018 and at times prior, at approximately  30 ft. employees were working on a scaffold with sections that did not have a mid rail.  The 39 inch cross member met the height of a top rail, but did not have a mid-rail.  Note: Abatement certification and documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 H02 II

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: Note:  This requirement does not apply to float (ship) scaffolds where an edging of 3/4 inch x 1 1/2 inch (2 x 4 cm) wood or equivalent was used in lieu of toe boards.  (a) 1812 N. Lakewood Dr.: On or about May 22, 2018 and at times prior, at approximately 30 ft. employees were installing brickwork from a scaffold and other contractors were working below at ground level.  Note: Abatement documentation and certification is required for this item.