Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ANIBAL LOPEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ANIBAL LOPEZ in 8882 COX RD., WEST CHESTER, OH 45069 (NAICS 238160). OSHA activity number 343202339.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Anibal Lopez — free Get an email when a new federal OSHA severe-injury report for Anibal Lopez is published. One employer, no account, unsubscribe in one click.
Establishment
ANIBAL LOPEZ
Site address
8882 COX RD.
City
WEST CHESTER
State
OH
ZIP
45069
Mailing
146 PRINCETON SQUARE CIR, SPRINGDALE, OH 45246
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 23, 2018
Penalty
Initial $3,326 · Current $3,326
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  On June 4, 2018 located on the north side of a residential structure, employees were exposed to a fall hazard while installing sheathing onto a low pitch residential roof without utilizing any fall protection system. Potential fall height was measured to be 9-2" with a roof pitch of 2/12.