Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DANHOF CHEVROLET, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DANHOF CHEVROLET, INC. in 6605 AMSTERDAM ROAD, MANHATTAN, MT 59741 (NAICS 441110). OSHA activity number 343202511.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Danhof Chevrolet, INC. — free Get an email when a new federal OSHA severe-injury report for Danhof Chevrolet, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6605 AMSTERDAM ROAD
City
MANHATTAN
State
MT
ZIP
59741
Mailing
6605 AMSTERDAM ROAD, MANHATTAN, MT 59741
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
18
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Other-than-serious 2 instances 2 exposed
Issued
Jun 28, 2018
Abate by
Aug 24, 2018
Penalty
Initial $2,956 · Current $2,956
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)  Danhof Chevrolet, Inc. Auto Repair Shop:  On or about June 4, 2018 and at times prior employees were exposed to struck by hazards while using the 17 1/2 Ton OTC hydraulic shop press.    b)  Danhof Chevrolet, Inc. Auto Repair Shop:  On or about June 4, 2018 and at times prior employees were exposed to struck by and caught in hazards while using the Accu-turn brake lathe.
Recent events (2)
  • — I (O) $2956
  • — Z (S) $2956

1910.253 B02 II

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Jun 28, 2018
Abate by
Jul 25, 2018
Penalty
Initial $2,217 · Current $0 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:  a)  Danhof Chevrolet, Inc. Automotive Repair Shop:  On or about June 4, 2018 and at times prior the employer failed to ensure that the acetylene and oxygen cylinders were stored at least 20 feet apart.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2217

1910.244 A01 II

Other-than-serious 1 instance 2 exposed
Issued
Jun 28, 2018
Abate by
Jul 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.244(a)(1)(ii): Rated load(s) of portable jack(s) were not legibly and permanently marked in a prominent location on the jack(s) by casting, stamping, or other suitable means:  a)  Danhof Chevrolet, Inc. Auto Repair Shop:  On or about June 4, 2018 and at times prior the employer failed to ensure the engine hoist was labeled with a legible load rating.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 I A

Other-than-serious 2 instances 5 exposed
Issued
Jun 28, 2018
Abate by
Jul 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  a)  Danhof Chevrolet, Inc. Automotive Repair Shop, South Electrical Panel:  On or about June 4, 2018 and at times prior the employer failed to ensure that the 120 Volt electrical panel maintained a 3 foot clear working space in front of the electrical panel.  b)  Danhof Chevrolet, Inc. Automotive Repair Shop, North Electrical Panel:  On or about June 4, 2018 and at times prior the employer failed to ensure that the 120 Volt electrical panel maintained a 3 foot clear working space in front of the electrical panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Danhof Chevrolet, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343202511.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.