OSHA Inspection: U.S. FOREST SERVICE, JUNEAU RANGER DISTRICT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. FOREST SERVICE, JUNEAU RANGER DISTRICT in 8510 MENDENHALL LOOP ROAD, JUNEAU, AK 99801 (NAICS 924120). OSHA activity number 343206744.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Forest Service, Juneau Ranger District — free Get an email when a new federal OSHA severe-injury report for U.S. Forest Service, Juneau Ranger District is published. One employer, no account, unsubscribe in one click.
Site address
8510 MENDENHALL LOOP ROAD
City
JUNEAU
State
AK
ZIP
99801
Mailing
8510 MENDENHALL LOOP ROAD, JUNEAU, AK 99801
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
75
Ownership type
D

5 citations on file for this inspection.

1910.213 C01

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 12, 2018
Abate by
Jul 11, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut.  Wood Shop, on or about 05 June 2018 and times prior thereto; a Rockwell Arbor Saw, model 34-395-313, serial number 1756928, did not have the splitter and guard assembly installed. This condition exposed employees to a caught in hazard.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 12, 2018
Abate by
Jul 11, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch.  Auto Shop, on or about 05 June 2018 and times prior thereto, a Van Dorn 10-inch ball bearing bench grinder, serial number 259327; tool rest was not properly adjusted to a maximum distance of one-eighth of an inch from the abrasive wheel. The gap between the abrasive wheel and work rest measured approximately three-quarters of an inch. This condition exposed employees to a caught in hazard.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 12, 2018
Abate by
Jul 11, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.  Auto Shop, on or about 05 June 2018 and times prior thereto, a Van Dorn 10-inch ball bearing bench grinder, serial number 259327; tongue guard distance was greater than 1/4 of an inch from the abrasive wheel. Tongue guard was approximately one-inch from the abrasive wheel. This condition exposed employees to a caught in hazard.
Recent events (1)
  • — Z (S) $0

1910.212 B

Other-than-serious 2 instances 10 exposed
Issued
Jun 12, 2018
Abate by
Jul 11, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving.  Auto Shop, on or about 05 June 2018 and times prior thereto, two instances were noted where machines were not securely mounted:       a. Workbench area; A Van Dorn 10-inch ball bearing bench grinder, serial number 259327 was not mounted to prevent movement.       b. Work bench area; A Delta Shopmaster Drill Press, model DP350, Serial number 200649-XL was not mounted to prevent movement.  This condition exposed employees to a struck by hazard.
Recent events (1)
  • — Z (O) $0

1910.334 A02 I

Other-than-serious 1 instance 10 exposed
Issued
Jun 12, 2018
Abate by
Jul 11, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).  Automotive Shop, on or about 05 June 2018 and times prior thereto; a 50-foot orange extension cord was missing the ground pin. This condition exposed employees to an electrical shock and electrical burn hazard.