Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ABP REMODELING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ABP REMODELING INC. in 160 BRAYMORE COURT, INVERNESS, IL 60010 (NAICS 238160). OSHA activity number 343207254.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ABP Remodeling INC. — free Get an email when a new federal OSHA severe-injury report for ABP Remodeling INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ABP REMODELING INC.
Site address
160 BRAYMORE COURT
City
INVERNESS
State
IL
ZIP
60010
Mailing
825 VILLAGE QUARTER ROAD #A4, WEST DUNDEE, IL 60118
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Oct 25, 2018
Abate by
Nov 29, 2018
Penalty
Initial $311 · Current $311
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   ABP Remodeling Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation Number            Item Number                    Abatement Date  01                                01                                   08/22/2018  01                                02                                   08/22/2018  01                                03                                  08/22/2018  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $311

1926.102 A01

Serious Gravity 5 4 instances 4 exposed
Issued
Aug 16, 2018
Abate by
Aug 22, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:          a) On or about June 5, 2018, employees were exposed to eye injury while operating pneumatic nail guns without the eye protection during roofing work.           In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2217

1926.300 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 16, 2018
Abate by
Aug 22, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.300(b)(2): Moving part(s) of equipment exposed to contact by employees or which otherwise created a hazard, were not guarded:      a) On or about June 5, 2018, employees were exposed to rotating parts on a gas operated hoist motor where the recoil assembly guard was detached from the unit.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2772

1926.501 B13

Serious Gravity 10 4 instances 4 exposed
Issued
Aug 16, 2018
Abate by
Aug 22, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):                a) On or about June 5, 2018, employees were exposed to the hazard of falling from a while performing roofing work from a first story roof having a ground to eave height of approximately 12 feet.  b) On or about June 5, 2018, employees were exposed to the hazard of falling from a while performing roofing work from a second story roof having a ground to eave height of approximately 21 feet.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 16, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:     a) On or about June 5, 2018, employees were exposed to the hazard of falling from an elevation of approximately 12 feet where a portable extension ladder provided for roof access and egress did not extend at least 3 feet above the landing surface of the roof deck.     No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $2217

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343207254.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.