OCONOMOWOC, WI —
OSHA Inspection: WOLF SIDING & WINDOWS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WOLF SIDING & WINDOWS in 1650 BROWN ST., OCONOMOWOC, WI 53066 (NAICS 238170). OSHA activity number 343212163.
Where did this inspection happen?
- Establishment
- WOLF SIDING & WINDOWS
- Site address
- 1650 BROWN ST.
- City
- OCONOMOWOC
- State
- WI
- ZIP
- 53066
- Mailing
- N8392 LITTLE COFFEE RD., WATERTOWN, WI 53094
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 8
- Ownership type
- A
Citations
11 citations on file for this inspection.
1903.19 D01
- Issued
- Abate by
- Penalty
- Initial $319.00 · Current $319.00
General-duty citation text
29 CFR 1903.19(d)(1): The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. (a) The employer failed to provide documentation to the Agency demonstrating that abatement is completed for the serious violations that were issued by the Agency.
Recent events (1)
- — Z (O) $319
1926.451 B03
- Issued
- Abate by
- Penalty
- Initial $1663.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling.Note: See exceptions in paragraphs (b)(3)(i) and (ii) of this section. (a) The employer did not ensure that a ladder jack scaffold was 14 inches or less from the face of the work.
Recent events (3)
- — F (O) $0
- — C (S) $1663
- — Z (S) $1663
1926.451 B04
- Issued
- Abate by
- Penalty
- Initial $1663.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(4): Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm): (a) The employer did not ensure the end of a platform that was part of a ladder jack scaffold system extended over its support by at least 6 inches.
Recent events (3)
- — F (O) $0
- — C (S) $1663
- — Z (S) $1663
1926.451 B05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform was able to support employees without tipping, or had guardrails which blocked employee access to the cantilevered end: (a) The employer did not ensure that a platform of a ladder jack scaffold did not extend more than 18 inches over its support.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $2772.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: (a) The employer did not ensure that a ladder jack scaffold was erected by a competent person.
Recent events (3)
- — F (O) $0
- — C (S) $2772
- — Z (S) $2772
1926.454 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person: (a) The employer did not ensure that a person who erected a ladder jack scaffold was trained by a competent person in the hazards associated with erecting, dismantling and working from a scaffold.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1926.452 K05
- Issued
- Abate by
- Penalty
- Initial $1663.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.452(k)(5): Scaffold platforms shall not be bridged one to another. (a) The employer did not ensure that two platforms of a ladder jack scaffold were not bridged together.
Recent events (3)
- — F (O) $0
- — C (S) $1663
- — Z (S) $1663
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $1520.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) The employer did not ensure that employees were trained in recognizing fall hazards and implementing fall protection when conducting siding work on a commercial building.
Recent events (3)
- — F (S) $1520
- — C (S) $3880
- — Z (S) $3880
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $7760.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) The employer did not ensure that employees were using fall protection when conducting siding work on a commercial building. Wolf Siding & Windows was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1250535, citation number 01, item number 01 and was affirmed as a final order on October 19, 2017, with respect to a workplace location at 11028 N. Mequon Dr., Mequon, WI 53092.
Recent events (3)
- — F (R) $3000
- — C (R) $7760
- — Z (R) $7760
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $5543.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) The employer did not ensure that a ladder used for access to an upper landing surface was at least 3 feet above the landing surface. Wolf Siding & Windows was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1053(b)(1), which was contained in OSHA inspection number 1250535, citation number 01, item number 02 and was affirmed as a final order on October 19, 2017, with respect to a workplace location at 11028 N. Mequon Dr., Mequon, WI 53092.
Recent events (3)
- — F (R) $3000
- — C (R) $5543
- — Z (R) $5543
1926.1060 A
- Issued
- Abate by
- Penalty
- Initial $5543.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. (a) The employer did not ensure that employees were trained in hazards associated with ladders. Wolf Siding & Windows was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1060(a), which was contained in OSHA inspection number 1250535, citation number 01, item number 03 and was affirmed as a final order on October 19, 2017, with respect to a workplace location at 11028 N. Mequon Dr., Mequon, WI 53092.
Recent events (3)
- — F (R) $0
- — C (R) $5543
- — Z (R) $5543
More inspections at WOLF SIDING & WINDOWS
WATERTOWN, WI—2005-04-26 00:00:00
WOLF SIDING & WINDOWS
PEWAUKEE, WI—2003-10-02 00:00:00
WOLF SIDING & WINDOWS
View WOLF SIDING & WINDOWS's full OSHA safety record →
More inspections in this industry (NAICS 238170)
EAST HAVEN, CT—2026-07-16 00:00:00
BIANCO & SONS, LLC
FORT LEE, NJ—2026-07-15 00:00:00
SJM GENERAL CONTRACTORS LLC
CLINTON, MO—2026-07-14 00:00:00
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14 00:00:00
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14 00:00:00
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
More inspections in WI
GREEN BAY, WI—2026-07-17 00:00:00
PTS CONTRACTORS, INC.
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343212163.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.