HEBER SPRINGS, AR —
OSHA Inspection: ST. JEANS INDUSTRIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ST. JEANS INDUSTRIES, INC. in 424 INDUSTRIAL PARK RD., HEBER SPRINGS, AR 72543 (NAICS 336399). OSHA activity number 343212668.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ST. JEANS INDUSTRIES, INC.
- Site address
- 424 INDUSTRIAL PARK RD.
- City
- HEBER SPRINGS
- State
- AR
- ZIP
- 72543
- Mailing
- 424 INDUSTRIAL PARK RD., HEBER SPRINGS, AR 72543
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336399
- Employees
- 205
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- Sep 21, 2018
- Abate by
- Oct 16, 2018
- Penalty
- Initial $5,488 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about June 5, 2018 and times prior thereto, the machine specific procedures, to include but not limited to, the Okuma VMC 12 were not reviewed annually for any deviations or changes. This condition exposed employees to caught in hazards in the event of an unexpected energatizon.
Recent events (2)
- — I (S) $3000
- — Z (S) $5488
1910.147 C06 II
- Issued
- Sep 21, 2018
- Abate by
- Oct 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:(a) On or about June 5, 2018 and times prior thereto, the employer did not certify that the machine specific procedures, to include but not limited to, the Okuma VMC 12 were reviewed annually. This condition exposed employees to caught in hazards in the event of an unexpected energatizon.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Sep 21, 2018
- Abate by
- Oct 16, 2018
- Penalty
- Initial $12,806 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about June 5, 2018 and times prior thereto, the Okuma VMC12 was not guarded in a way that protected employees performing live maintenance from having their hands in a point operation during the operation cycle. This exposed employees to caught in hazards.
Recent events (2)
- — I (S) $7000
- — Z (S) $12806
More inspections in this industry (NAICS 336399)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343212668.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.