LANCASTER, PA —
OSHA Inspection: AG HOME IMPROVEMENT, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AG HOME IMPROVEMENT, INC. in 587 LAUREL LANE, LANCASTER, PA 17601 (NAICS 236118). OSHA activity number 343214243.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AG HOME IMPROVEMENT, INC.
- Site address
- 587 LAUREL LANE
- City
- LANCASTER
- State
- PA
- ZIP
- 17601
- Mailing
- 918 ELMHURST AVENUE, BRISTOL, PA 19007
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.20 B02
- Issued
- Sep 6, 2018
- Abate by
- Oct 2, 2018
- Penalty
- Initial $2,217 · Current $1,333 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person: (a) 587 Laurel Lane, Lancaster, Pennsylvania - The employer did not have a competent person involved in the job site in that none of the employees who worked on the site on June 8, 2018 inspected the job site, identified predictable fall hazards, and took immediate actions to correct the hazards. As a result, employees did residential roofing work without using any fall protection system, and employees used portable extension ladders that did not extend three feet above the landing surface to access the roof, exposing employees to the hazard of falling to a lower level, on or about June 8, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1333
- — Z (S) $2217
1926.501 B13
- Issued
- Sep 6, 2018
- Abate by
- Oct 2, 2018
- Penalty
- Initial $2,217 · Current $1,334 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): (a) Roof - Employees worked removing the old roofing and installing new roofing on the two-story single-family home and on the one-and-a-half-story attached garage. The employees did not use any fall protection, exposing them to the hazard of falling from the roof to the ground below, on or about June 8, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1334
- — Z (S) $2217
1926.1053 B01
- Issued
- Sep 6, 2018
- Abate by
- Oct 2, 2018
- Penalty
- Initial $2,217 · Current $1,333 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Roof over Garage - Two employees used a portable extension ladder to gain access to the roof to tear off the old roofing. This ladder did not extend three feet above the roof (upper landing) surface, exposing the employees to the hazard of falling about 9 feet to the ground below, on or about June 8, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1333
- — Z (S) $2217
More inspections at AG Home Improvement, INC.
View AG Home Improvement, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343214243.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.