Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUIETFLEX MANUFACTURING COMPANY, LP

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of QUIETFLEX MANUFACTURING COMPANY, LP in 4518 BRITTMOORE RD., HOUSTON, TX 77041 (NAICS 327993). OSHA activity number 343218962.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quietflex Manufacturing Company, LP — free Get an email when a new federal OSHA severe-injury report for Quietflex Manufacturing Company, LP is published. One employer, no account, unsubscribe in one click.
Site address
4518 BRITTMOORE RD.
City
HOUSTON
State
TX
ZIP
77041
Mailing
4518 BRITTMOORE RD., HOUSTON, TX 77041
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327993
Employees
41
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II D

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Jul 27, 2018
Abate by
Aug 15, 2018
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy controls:   On or about June 7, 2018, at matline #1 where employees were exposed to amputation and caught-in hazards when performing a shift clean-up on blend line #6 without outlining the procedural steps for testing and verifying the blend line rollers had stopped rotating.
Recent events (3)
  • — F (S) $0
  • — C (S) $12934
  • — Z (S) $12934

1910.147 D03

Other-than-serious 1 instance 1 exposed
Issued
Jul 27, 2018
Abate by
Aug 15, 2018
Penalty
Initial $0 · Current $12,934
29 CFR 1910.147(d)(3):     All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:    On or about June 7, 2018, at matline #1
Recent events (3)
  • — F (O) $12934
  • — C (S) $0
  • — Z (S) $0

1910.147 D03

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Jul 27, 2018
Abate by
Aug 15, 2018
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):   On or about June 7, 2018 and times prior to, at matline #1 where employees were exposed to amputation and caught-in hazards when performing shift clean-ups on blending lines without using all the energy isolating devices.
Recent events (3)
  • — F (S) $0
  • — C (S) $12934
  • — Z (S) $12934

View Quietflex Manufacturing Company, LP's full OSHA safety record →