Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LAKE GM AUTO CENTER

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of LAKE GM AUTO CENTER in 123 FIFTH STREET NE, DEVILS LAKE, ND 58301 (NAICS 441110). OSHA activity number 343220679.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lake GM Auto Center — free Get an email when a new federal OSHA severe-injury report for Lake GM Auto Center is published. One employer, no account, unsubscribe in one click.
Establishment
LAKE GM AUTO CENTER
Site address
123 FIFTH STREET NE
City
DEVILS LAKE
State
ND
ZIP
58301
Mailing
P.O. BOX 987, DEVILS LAKE, ND 58301
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
35
Ownership type
A

2 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 3, 2018
Abate by
Aug 29, 2018
Penalty
Initial $3,880 · Current $1,940 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a)   On or about June 7, 2018 and at times prior, for the employees exposed to physiological stress while wearing a negative-pressure respirator and painting cars in a paint booth at 123 Fifth Street NE Devils Lake, ND.
Recent events (2)
  • — I (S) $1940
  • — Z (S) $3880

1910.107 F01

Other-than-serious 1 instance 1 exposed
Issued
Aug 3, 2018
Abate by
Aug 29, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.107(f)(1): In sprinklered buildings, the automatic sprinkler system in rooms containing spray finishing operations did not conform to the requirements of 1910.159 in that the fire suppression systems were not hooked up:  (a)   On or about June 7, 2018 and at times prior for the employees exposed to fire and explosion hazards while spray painting vehicles in a spray paint booth that did not have a suppression system at 123 Fifth Street NE Devils Lake, ND.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Lake GM Auto Center's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343220679.