Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VIGILANTE ENTERPRISES, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of VIGILANTE ENTERPRISES, INC. in 1214 BRISTOL PIKE, BENSALEM, PA 19020 (NAICS 447190). OSHA activity number 343226387.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vigilante Enterprises, INC. — free Get an email when a new federal OSHA severe-injury report for Vigilante Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1214 BRISTOL PIKE
City
BENSALEM
State
PA
ZIP
19020
Mailing
1214 BRISTOL PIKE, BENSALEM, PA 19020
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
447190
Employees
11
Ownership type
A

8 citations on file for this inspection.

1910.146 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 16, 2018
Abate by
Mar 1, 2019
Penalty
Initial $12,934 · Current $10,000 Reduced

Hazardous substances 1340

29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:    a) Underground concrete vaults and steel gasoline tanks numbers 1, 2, & 3  - On or about June 12, 2018, the employer did not properly evaluate underground tank vaults to determine if they were permit-required confined spaces, and ensuring acceptable entry conditions were met before employees were permitted to conduct entry and attendant activities.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $12934

1910.146 C04

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 16, 2018
Abate by
Mar 1, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 1340

29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:    a) Underground concrete vaults and steel gasoline tanks numbers 1, 2, & 3.  - On or about June 12, 2018, the employer did not develop and implement a written permit space entry program for hazards associated with employees performing entry and attendant duties for three underground concrete vaults containing gasoline storage tanks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.307 C02 I

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 16, 2018
Abate by
Dec 3, 2018
Penalty
Initial $12,934 · Current $8,500 Reduced
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was or could be present:    a) Underground concrete vault with steel gasoline tank #2  - On or about June 12, 2018, an employee entered the vault, classified as a hazardous Class 1, Division 2 location, and operated a Ridgid shop vacuum which was not approved for classified locations.
Recent events (2)
  • — I (S) $8500
  • — Z (S) $12934

1910.1200 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 16, 2018
Abate by
Dec 3, 2018
Penalty
Initial $2,217 · Current $1,492 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) Vigilante Enterprises, Inc. - On or about June 12, 2018, the employer did not develop, implement, and maintain at the workplace a written hazard communication program for employees using chemicals associated with auto maintenance and repair.
Recent events (2)
  • — I (S) $1492
  • — Z (S) $2217

1910.1200 H01

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 16, 2018
Abate by
Dec 3, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Vigilante Enterprises, Inc. - On or about June 12, 2018, employees were not provided with effective information and training on hazardous chemicals in their work area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B01 I

Other-than-serious 1 instance 1 exposed
Issued
Nov 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:  a) Shop area, Mezzanine - On or about June 12, 2018, the employer did not ensure that a sufficient guardrail system was installed on the corner of a mezzanine, above the stairway access area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.29 F04

Other-than-serious 1 instance 1 exposed
Issued
Nov 16, 2018
Abate by
Dec 3, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.29(f)(4): An opening in a stair rail system exceeded 19 inches at its least dimension:  a) Shop area, Mezzanine - On or about June 12, 2018, the opening in a stair rail system constructed of steel pipe did not have a mid-rail or other intermediate vertical members installed resulting in an opening exceeding 19 inches.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C01

Other-than-serious 1 instance 1 exposed
Issued
Nov 16, 2018
Abate by
Jan 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    a) Underground concrete vaults and steel gasoline tanks numbers 1, 2, & 3  - On or about June 12, 2018, the employer did not properly evaluate the underground tank vaults to determine if they would be permit-required confined spaces requiring appropriate measures to ensure that acceptable entry conditions were met before employees were allowed to conduct entry and attendant activities.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343226387.