LITHONIA, GA —
OSHA Inspection: JFA CONSTRUCTION, LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of JFA CONSTRUCTION, LLC in 3738 HOLLOW OAK LANE, LITHONIA, GA 30038 (NAICS 238160). OSHA activity number 343226866.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JFA CONSTRUCTION, LLC
- Site address
- 3738 HOLLOW OAK LANE
- City
- LITHONIA
- State
- GA
- ZIP
- 30038
- Mailing
- 4043 DORAL DRIVE, DORAVILLE, GA 30360
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.416 A03
- Issued
- Nov 29, 2018
- Abate by
- Dec 26, 2018
- Penalty
- Initial $12,934 · Current $12,000 Reduced
General-duty citation text
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit. a) Site - On or about 06/11/18 and at times prior thereto employees engaged in roofing work came in close proximity of the uninsulated crimped splice terminals connecting the 120V/240V service drop from the pole transformer to the house meter, and the employer did not assess the electrical hazards prior to the commencement of the work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $12000
- — Z (S) $12934
1926.416 A01
- Issued
- Nov 29, 2018
- Abate by
- Dec 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(1): The employer permitted employees to work in proximity of electric power circuits that the employees could contact during the course of work, and the employees were not protected against electric shock by de-energizing the circuit and grounding it, or by guarding it effectively by insulation or other means. a) Site - On or about 06/11/18 and at times prior thereto employees engaged in roofing work came in close proximity of the uninsulated crimped splice terminals connecting the 120V/240V service drop from the pole transformer to the house meter, and the employer did not protect employees from accidental contact with energized parts. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B12
- Issued
- Nov 29, 2018
- Abate by
- Dec 26, 2018
- Penalty
- Initial $3,880 · Current $2,016 Reduced
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails a) Site - On or about 06/11/18 and at times prior thereto employees engaged in roofing work came in close proximity of the uninsulated crimped splice terminals connecting the 120V/240V service drop from the pole transformer to the house meter. An extensible aluminum ladder was used to reach the roof eave. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2016
- — Z (S) $3880
1926.1060 A
- Issued
- Nov 29, 2018
- Abate by
- Dec 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. a) Site - On or about 06/09/18 and at times prior thereto employees engaged in roofing work utilized ladders to access sloped roofs and came in close proximity of uninsulated sections of electrical lines. The employer did not develop, implement, and enforce a training program that would enable employees to recognize and eliminate hazards associated with the use of ladders. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.39 A01
- Issued
- Nov 29, 2018
- Penalty
- Initial $2,772 · Current $0 Reduced
General-duty citation text
29 CFR 1904.39(a)(1): The employer did not report within 8-hours the death of an employee resulting from a work-related incident: The fatality recorded at 8:12 PM on 06/09/18 was reported to OSHA at 11:45 AM on 06/10/18.
Recent events (2)
- — I (O) $0
- — Z (O) $2772
More inspections at JFA Construction, LLC
View JFA Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343226866.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.