HUNTINGDON VALLEY, PA —
OSHA Inspection: GERMANTOWN TOOL AND MACHINE SHOP, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GERMANTOWN TOOL AND MACHINE SHOP, INC. in 1681 REPUBLIC ROAD, HUNTINGDON VALLEY, PA 19006 (NAICS 332999). OSHA activity number 343227963.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GERMANTOWN TOOL AND MACHINE SHOP, INC.
- Site address
- 1681 REPUBLIC ROAD
- City
- HUNTINGDON VALLEY
- State
- PA
- ZIP
- 19006
- Mailing
- 1681 REPUBLIC ROAD, HUNTINGDON VALLEY, PA 19006
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 30
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Jul 2, 2018
- Abate by
- Sep 23, 2018
- Penalty
- Initial $7,853 · Current $4,800 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: a) Worksite - On or about June 14, 2018, maintenance employees were performing work on equipment such as, but not limited to, press brakes, power presses, and shears, while using energy control procedures that did not specifically outline the scope, purpose, authorization, rules, and techniques needed to effectively control the various energy hazards present within the production and support equipment.
Recent events (2)
- — I (S) $4800
- — Z (S) $7853
1910.147 C06 I
- Issued
- Jul 2, 2018
- Abate by
- Sep 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Worksite - On or about June 14, 2018, maintenance employees perform work on equipment such as, but not limited to, press brakes, power presses, and shears, but employer did not ensure that a periodic inspection of the energy control procedures at least annually. Abatement Note: Where lockout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.