Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AVALON MAINTENANCE, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AVALON MAINTENANCE, LLC in W. CONEJOS PL. BETWEEN JULIAN & KING ST., DENVER, CO 80204 (NAICS 237110). OSHA activity number 343240131.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Avalon Maintenance, LLC — free Get an email when a new federal OSHA severe-injury report for Avalon Maintenance, LLC is published. One employer, no account, unsubscribe in one click.
Site address
W. CONEJOS PL. BETWEEN JULIAN & KING ST.
City
DENVER
State
CO
ZIP
80204
Mailing
4815 BRANDON ACRES LANE, BUFORD, GA 30519
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.651 K01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 28, 2018
Abate by
Oct 24, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.651(k)(1):  Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres and or other hazardous conditions:    (a) Avalon Maintenance, LLC, at W. Conejos Pl. between Julian and King Streets, Denver, CO 80204:  On or before June 13, 2018, the exposing employer did not ensure that daily inspections of a trench, that was approximately 7.5 feet deep, and the adjacent area were made by the competent person for evidence of a situation that could have resulted in a hazardous condition.  The competent person did not identify that the trench had near vertical walls and water at the bottom of the trench.  This condition exposed employees to a crushing and struck-by hazard from excavation wall cave-in.     Note:  "Competent person" means one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them.
Recent events (1)
  • — Z (S) $2772

1926.652 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 28, 2018
Abate by
Oct 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.652(a)(1):  Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c):  (a)   Avalon Maintenance, LLC, at W. Conejos Pl. between Julian and King Streets, Denver, CO 80204:  On or before June 13, 2018, the exposing employer did not ensure that each employee conducting work in an excavation was protected from cave-in, in that work performed to uncover a sewer line main in preparation to make a tie-in and install a manhole vault was done in the area of the trench that was approximately 7.5 feet deep, had water at the bottom, and lacked a protective system.  This condition exposed employees to a crushing and struck-by hazard from excavation wall cave-in.