PATERSON, NJ —
OSHA Inspection: KONOPKA CONSTRUCTION INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KONOPKA CONSTRUCTION INC in 1089 MAIN ST, PATERSON, NJ 07503 (NAICS 238140). OSHA activity number 343242608.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KONOPKA CONSTRUCTION INC
- Site address
- 1089 MAIN ST
- City
- PATERSON
- State
- NJ
- ZIP
- 07503
- Mailing
- 122 FRANCES PL, HILLSIDE, NJ 07205
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 10
- Ownership type
- A
Citations
11 citations on file for this inspection.
1926.56 A
- Issued
- Sep 18, 2018
- Penalty
- Initial $3,880 · Current $2,328 Reduced
General-duty citation text
29 CFR 1926.56(a): While work was in progress, construction areas, ramps, runways, corridors, offices, shops or storage areas were not lighted to the minimum illumination intensities as listed in Table D-3 of 29 CFR 1926.56 - 3 foot candles; accessways: a) Interior Stairway - 1st Floor to 4th Floor: Employees engaged in masonry activities in the Main St. Elevation were exposed to tripping hazards by utilizing the four story dark metal stairway to access the working area, on or about 6/1/18. b) Interior Stairway - 1st Floor to 4th Floor: Employees engaged in masonry activities in the Main St. Elevation were exposed to tripping hazards by utilizing the four story dark metal stairway to access the working area, on or about 6/7/18.
Recent events (2)
- — I (S) $2328
- — Z (S) $3880
1926.404 F06
- Issued
- Sep 18, 2018
- Penalty
- Initial $1,663 · Current $998 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Exterior of Building - First Floor: Employees were exposed to electric shock while utilizing an extension cord that had a missing ground pin to energize an electric mixer and battery chargers, on or about 6/1/18.
Recent events (2)
- — I (S) $997.8
- — Z (S) $1663
1926.405 A02 II E
- Issued
- Sep 18, 2018
- Penalty
- Initial $1,663 · Current $998 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): All lamps for temporary illumination were not protected from accidental contact or breakage: a) Interior Stairway: Several of the energized temporary lights were not protected by cages, on or about 6/9/18
Recent events (2)
- — I (S) $997.8
- — Z (S) $1663
1926.451 D03 VI
- Issued
- Sep 18, 2018
- Penalty
- Initial $3,880 · Current $2,328 Reduced
General-duty citation text
29 CFR 1926.451(d)(3)(vi): Outrigger beams which are not stabilized by bolts or other direct connections to the floor or roof deck were not secured by tiebacks: a) Main St. Façade - Suspended Scaffold: Employees engaged in masonry activity from a suspended scaffold platform were exposed to fall hazards of approximately 25 feet as the two outrigger beams were not bolted and not tied back, on or about 6/1/18
Recent events (2)
- — I (S) $2328
- — Z (S) $3880
1926.451 F07
- Issued
- Sep 18, 2018
- Penalty
- Initial $3,880 · Current $2,328 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) Main St. Façade - Suspended Scaffold: Employees engaged in masonry activity from a suspended scaffold platform were exposed to fall hazards of approximately 25 feet as the suspended scaffold had many inadequacies and been installed without the supervision of a competent person, on or about 6/1/18 b) Buffalo St. Façade - Suspended Scaffold: Employees engaged in masonry activity from a suspended scaffold platform were exposed to fall hazards of approximately 20 feet as the suspended scaffold had many inadequacies and been installed without the supervision of a competent person, on or about 6/9/18
Recent events (2)
- — I (S) $2328
- — Z (S) $3880
1926.451 D03 IV
- Issued
- Sep 18, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(d)(3)(iv): Counterweights were not secured by mechanical means to the outrigger beams to prevent accidental displacement: a) Main St. Façade - Suspended Scaffold: Employees engaged in masonry activity from a suspended scaffold platform were exposed to fall hazards of approximately 25 feet as the counterweights on the two outrigger beams were not mechanically secured, on or about 6/1/18 b) Buffalo St. Façade - Suspended Scaffold: Employees engaged in masonry activity from a suspended scaffold platform were exposed to fall hazards of approximately 20 feet as the counterweights on the two outrigger beams were not mechanically secured, on or about 6/9/18
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 D03 X
- Issued
- Sep 18, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(d)(3)(x): Single tiebacks were installed at an angle: a) Buffalo St. Façade - Suspended Scaffold: Employees engaged in masonry activity from a suspended scaffold platform were exposed to fall hazards of approximately 20 feet as the two outrigger beams were tied back with single angled tiebacks, on or about 6/9/18
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G03 I
- Issued
- Sep 18, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion. a) Main St. Façade - Suspended Scaffold: Employees engaged in masonry activity from a suspended scaffold platform were exposed to fall hazards as the two lifelines were not protected at the edge of the parapet, on or about 6/1/18 b) Buffalo St. Façade - Suspended Scaffold: Employees engaged in masonry activity from a suspended scaffold platform were exposed to fall hazards as the two lifelines were not protected at the edge of the parapet, on or about 6/9/18
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 H02 II
- Issued
- Sep 18, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: a) Buffalo St. Façade - Suspended Scaffold: Employees were engaged in masonry activity from a suspended scaffold platform approximately 20 feet above the ground without a toeboard or netting, on or about 6/9/18
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G03 IV
- Issued
- Sep 18, 2018
- Penalty
- Initial $2,772 · Current $1,663 Reduced
General-duty citation text
29 CFR 1926.451(g)(3)(iv): Vertical lifelines were attached to each other and to the same point of anchorage. a) Main St. Façade - Suspended Scaffold: Employees engaged in masonry activity from a suspended scaffold platform were exposed to fall hazards of approximately 25 feet as the two lifelines were attached to each other and to one only anchor point, on or about 6/1/18
Recent events (2)
- — I (S) $1663.2
- — Z (S) $2772
1926.1052 B01
- Issued
- Sep 18, 2018
- Penalty
- Initial $3,880 · Current $2,328 Reduced
General-duty citation text
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan. a) Interior Stairway - 1st Floor to 4th Floor: Employees engaged in masonry activities in the Main St. facade were exposed to tripping hazards by utilizing the four story unfiled metal stairway to access the working area, on or about 6/1/18. b) Interior Stairway - 1st Floor to 4th Floor: Employees engaged in masonry activities in the Main St. facade were exposed to tripping hazards by utilizing the four story unfiled metal stairway to access the working area, on or about 6/7/18. c) Interior Stairway - 1st Floor to 4th Floor: Employees engaged in masonry activities in the Buffalo St. facade were exposed to tripping hazards by utilizing the four story unfiled metal stairway to access the working area, on or about 6/9/18.
Recent events (2)
- — I (S) $2328
- — Z (S) $3880
More inspections at Konopka Construction INC
View Konopka Construction INC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343242608.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.