Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAUL HERNANDEZ CRUZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAUL HERNANDEZ CRUZ in 4415 CENTRAL COLLEGE ROAD, WESTERVILLE, OH 43081 (NAICS 238160). OSHA activity number 343244794.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Raul Hernandez Cruz — free Get an email when a new federal OSHA severe-injury report for Raul Hernandez Cruz is published. One employer, no account, unsubscribe in one click.
Establishment
RAUL HERNANDEZ CRUZ
Site address
4415 CENTRAL COLLEGE ROAD
City
WESTERVILLE
State
OH
ZIP
43081
Mailing
4827 HEATH TRAILS ROAD, HILLIARD, OH 43026
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 5, 2018
Abate by
Aug 9, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.     a. On or about June 21, 2018, at an existing residential home site, the employer did not initiate and maintain safety programs which addressed fall protection during roofing activities.
Recent events (2)
  • — I (S) $2772
  • — Z (S) $2772

1926.501 B13

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 5, 2018
Abate by
Jul 17, 2018
Penalty
Initial $2,772 · Current $0 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.   Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.     a. On or about June 21, 2018, at an existing residential home site, the employer did not ensure that employees involved in roofing activities were protected against falls up to 18 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2772

1926.21 B02

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 5, 2018
Abate by
Jul 17, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.      a. On or about June 21, 2018, at an existing residential home site, the employer did not instruct each employee performing roofing activities above 6 feet in the recognition and avoidance of unsafe conditions and the regulations applicable to their work environment to control or eliminate any hazards or other exposure to falls.
Recent events (2)
  • — I (S) $2772
  • — Z (S) $2772

1926.1053 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 5, 2018
Abate by
Jul 17, 2018
Penalty
Initial $2,772 · Current $0 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.     a. On or about June 21, 2018, at an existing residential home site, the employer did not ensure that the Werner aluminum extension ladder used by employees to access the roof extended at least 3 feet above the upper landing surface to prevent employees from falling 11 feet, 3 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2772

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343244794.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.