Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUKASZ ZOCHOWSKI DBA LUKE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LUKASZ ZOCHOWSKI DBA LUKE in 2257 N. LINCOLN AVE., CHICAGO, IL 60614 (NAICS 238140). OSHA activity number 343250676.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lukasz Zochowski DBA Luke — free Get an email when a new federal OSHA severe-injury report for Lukasz Zochowski DBA Luke is published. One employer, no account, unsubscribe in one click.
Site address
2257 N. LINCOLN AVE.
City
CHICAGO
State
IL
ZIP
60614
Mailing
31 W DEMPSTER ST., DES PLAINES, IL 60016
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Dec 17, 2018
Penalty
Initial $2,217 · Current $0 Reduced
29 CFR 1926.100(a): Employee(s) were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:  a) On June 25, 2018, employees were not wearing protective helmets while working below employees performing masonry work on a tubular welded frame scaffold.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2217

1926.451 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 17, 2018
Penalty
Initial $3,880 · Current $1,950 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds were not fully planked or decked between the front uprights and the guardrail supports:    a) On June 25, 2018, employees were exposed to the hazard of falling greater than 17 feet while performing masonry work from scaffold platforms which were not fully planked.
Recent events (2)
  • — I (S) $1950
  • — Z (S) $3880

1926.451 G01

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 17, 2018
Abate by
Dec 21, 2018
Penalty
Initial $3,880 · Current $1,950 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level:    a) On June 25, 2018, employees were exposed to the hazard of falling greater than 17 feet while performing masonry work from scaffolding without fall protection equipment such as guardrails installed on the working level.
Recent events (2)
  • — I (S) $1950
  • — Z (S) $3880

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 17, 2018
Abate by
Dec 21, 2018
Penalty
Initial $2,772 · Current $0 Reduced
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet above or below the point of access:    a) On June 25, 2018, employees accessed scaffold platforms greater than 17 feet above the ground by climbing the ends of the scaffold frames that were not designed for such use, the cross bracing, and guardrails.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2772

1926.404 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Dec 17, 2018
Abate by
Dec 21, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): All 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which were used by employees did not have approved ground-fault circuit interrupters for personnel protection (NOTE: Receptacles on a two-wire, single-phase portable or vehicle-mounted generator not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.):  a) On June 25, 2018, employees were using a Homelite 120/240 volt single-phase 6300 watt three-wire gas powered generator to provide electric power at the site without ground-fault circuit interrupters.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.502 D15

Other-than-serious 1 instance 2 exposed
Issued
Dec 17, 2018
Abate by
Dec 21, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:  a) On June 25, 2018, the employer did not ensure that the anchorage used by employees as an attachment point for the personal fall arrest system was capable of supporting at least 5,000 pounds per employee attached to it.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.503 B01

Other-than-serious 1 instance 3 exposed
Issued
Dec 17, 2018
Abate by
Jan 22, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:  a) On or about June 25, 2018, the employer did not maintain records or certification of fall protection training for employees exposed to fall hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Lukasz Zochowski DBA Luke's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343250676.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.