Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AVERY RENTAL PROPERTIES, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AVERY RENTAL PROPERTIES, LLC. in 96 WEST 6TH STREET, OSWEGO, NY 13126 (NAICS 238990). OSHA activity number 343252193.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Avery Rental Properties, LLC. — free Get an email when a new federal OSHA severe-injury report for Avery Rental Properties, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
96 WEST 6TH STREET
City
OSWEGO
State
NY
ZIP
13126
Mailing
BEACON HOTEL 75 WEST BRIDGE STREET, OSWEGO, NY 13126
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
11
Ownership type
A

5 citations on file for this inspection.

1926.403 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 10, 2018
Abate by
Aug 17, 2018
Penalty
Initial $3,696 · Current $400 Reduced
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose.    a)  At the jobsite, on or about 6/21/18:  Workers were using job built power cords that had duplex outlets wired into them which were not designed for this purpose.
Recent events (3)
  • — J (S) $400
  • — C (S) $3696
  • — Z (S) $3696

1926.405 A02 II E

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 10, 2018
Abate by
Aug 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:    a)  At the jobsite, on or about 6/21/18:  Employees were working in an area lit with temporary lighting and where the bulbs were not protected from accidental contact or breakage.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.501 B01

Serious Gravity 10 2 instances 4 exposed
Issued
Aug 10, 2018
Abate by
Aug 16, 2018
Penalty
Initial $5,174 · Current $550 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    a)  At the jobsite, on the second floor, on or about 6/21/18:  Workers were stepping out onto a roof approximately 12 feet from ground, without fall protection, to dump rubble onto the ground from the demolished chimney.     b)  At the jobsite, on the second floor, on or about 6/21/18:  Workers were removing rubble and debris from the area while in close proximity to an unprotected wall opening approximately 12 feet from ground.
Recent events (3)
  • — J (S) $550
  • — C (S) $5174
  • — Z (S) $5174

1926.850 A

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 10, 2018
Abate by
Aug 30, 2018
Penalty
Initial $3,696 · Current $400 Reduced
29 CFR 1926.850(a): Evidence in writing was not available that an engineering survey performed by a competent person had been performed prior to permitting employee(s) to start demolition operations:(a)(IDENTIFY LOCATION(S))    a)  At the jobsite, on the second floor, on or about 6/21/18:  Workers were performing demolition of stud walls, removal of plaster and drywall from stud walls, and the demolition and removal of a masonry chimney, 3 stories high without, being provided an engineering survey to ensure that the structure was safe for demolition.
Recent events (3)
  • — J (S) $400
  • — C (S) $3696
  • — Z (S) $3696

1926.1052 C01 I

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 10, 2018
Abate by
Aug 16, 2018
Penalty
Initial $3,696 · Current $400 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:    a)  At the jobsite, accessing the second floor, on or about 6/21/18:  Workers were using a stairwell between the first and second floors without being provided a handrail.
Recent events (3)
  • — J (S) $400
  • — C (S) $3696
  • — Z (S) $3696

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343252193.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.