Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MARIPOSA LABS LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MARIPOSA LABS LLC in 270 E 50TH ST, GARDEN CITY, ID 83714 (NAICS 325620). OSHA activity number 343252920.

Watch Mariposa Labs LLC — free Get an email when a new federal OSHA severe-injury report for Mariposa Labs LLC is published. One employer, no account, unsubscribe in one click.
Establishment
MARIPOSA LABS LLC
Site address
270 E 50TH ST
City
GARDEN CITY
State
ID
ZIP
83714
Mailing
270 E 50TH ST, GARDEN CITY, ID 83714
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325620
Employees
57
Ownership type
A

4 citations on file for this inspection.

1910.212 B

Serious Gravity 1 4 instances 1 exposed
Issued
Penalty
Initial $3298.00 · Current $2309.00 Reduced
29 CFR 1910.212(b):  Machines designed for a fixed location were not securely anchored to prevent walking or moving.  a) On or about June 26, 2018 or prior thereto, Production Area:  Low pressure steam tank #6 was not anchored.  b) On or about June 26, 2018 or prior thereto, Production Area:  Low pressure steam tank #7 was not anchored.  c) On or about June 26, 2018 or prior thereto, Production Area:  Low pressure steam tank #9 was not anchored.  d) On or about June 26, 2018 or prior thereto, Production Area:  Low pressure steam tank #10 was not anchored.  NOTE:  Abatement certification is NOT required for this item.
Recent events (2)
  • — I (S) $2308.6
  • — Z (S) $3298

1910.132 D02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.  a) On or about June 26, 2018, or prior thereto:   The employer had not completed a certified personal protective equipment assessment.    Eye and face protection are required in the Production Area, Packaging, and the QA Lab.  NOTE:  Abatement certification is NOT required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  a) On or about June 26, 2018 or prior thereto:   A periodic inspection of the employer's energy control procedures had not been completed.   Lockout procedures have been conducted on Tank #3 in Production, and the Oden Filler.   Pneumatic and electrical lockouts have been performed.  NOTE:   Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L04 III

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance had not been conducted at least once every three years.  a) On or about June 26, 2018 or prior thereto:  Employees operate Crown Powered Industrial Trucks Model RC 3020-40, Serial Number 1A243806; and Model 35RCTT, Serial Number 1A159538.   Employee operators were not trained at least once every three years.  NOTE:  Abatement certification is NOT required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343252920.