AMARILLO, TX —
OSHA Inspection: GALINDOS CONSTRUCTION
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of GALINDOS CONSTRUCTION in 5601 BOYCE CT, AMARILLO, TX 79101 (NAICS 238140). OSHA activity number 343260667.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GALINDOS CONSTRUCTION
- Site address
- 5601 BOYCE CT
- City
- AMARILLO
- State
- TX
- ZIP
- 79101
- Mailing
- 2004 NW 20TH AVE, AMARILLO, TX 79101
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 F03
- Issued
- Oct 9, 2018
- Abate by
- Oct 29, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about 28 June 2018 at the worksite in Amarillo Texas the employer allowed employees to utilize a scaffold system that had not been inspected for defects by a competent person while performing masonry work on the roof of the structure at a height of approximately 18 feet
Recent events (2)
- — I (S) $3880
- — Z (S) $3880
1926.451 B01
- Issued
- Oct 9, 2018
- Abate by
- Oct 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no(a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)(DESCRIBE HAZARDS WHERE NECESSARY) On or about 28 June 2018 at the Amarillo site the employer allowed employees to utilize a scaffold that was not fully planked to perform masonry work at a height of 18 feet
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B05 I
- Issued
- Oct 9, 2018
- Abate by
- Oct 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length, extended over its support more than 12 inches:Note: Does not apply if the platform was designed and installed so that the cantilevered portion of the platform was able to support employees and/or materials without tipping or had guardrails that blocked employee access to the end. On or about 28 June 2018 at the Amarillo site the employer allowed employees to utilize a scaffold whose planks extended more than 12 inches past the bearers to perform masonry work at a height of 18 feet
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B08
- Issued
- Oct 9, 2018
- Abate by
- Oct 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(8): At all points of a scaffold where the platform changes direction, such as turning a corner, the platform that rests on a bearer at an angle other than a right angle was not laid first, and platforms which rest at right angles over t(a) On or about 28 June 2018 at the Amarillo site the employer allowed employees to utilize a scaffold whose planks set perpendicular to the planks at the changes of direction were not laid over the bearers to perform masonry work at a height of 18 feet
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Oct 9, 2018
- Abate by
- Oct 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. On or about 28 June 2018 at the Amarillo site the employer allowed employees to utilize a scaffold that did not have ladders or other approved methods of egress or access to perform masonry work at a height of 18 feet
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Oct 9, 2018
- Abate by
- Oct 29, 2018
- Penalty
- Initial $3,880 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b) On or about 28 June 2018 at the Amarillo site the employer allowed employees to work on the roof of the structure without adequate fall protection to perform masonry work at a height of 18 feet
Recent events (2)
- — I (S) $0
- — Z (S) $3880
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343260667.