Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CHOICE FABRICATORS, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CHOICE FABRICATORS, INC. in 3155 STEELE STATION ROAD, RAINBOW CITY, AL 35906 (NAICS 336370). OSHA activity number 343264172.

Watch Choice Fabricators, INC. — free Get an email when a new federal OSHA severe-injury report for Choice Fabricators, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3155 STEELE STATION ROAD
City
RAINBOW CITY
State
AL
ZIP
35906
Mailing
3155 STEELE STATION ROAD, RAINBOW CITY, AL 35906
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336370
Employees
258
Ownership type
A

3 citations on file for this inspection.

1910.67 C02 V

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $12934.00 · Current $10000.00 Reduced
29 CFR 1910.67(c)(2)(v): A personal fall arrest or travel restraint system that meets the requirements in subpart I of this part was not worn and attached to the boom or basket when working from an aerial lift:    a) On or about 6/27/2018 - in the Small Progressive Department, a Maintenance Technician was exposed to a fall hazard of approximately 24 feet without using fall protection while changing out a light fixture using a Snorkel Lift (Model ATB 46n, Serial No. 963192).
Recent events (2)
  • — I (S) $10000
  • — Z (S) $12934

1910.333 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $12934.00 · Current $10000.00 Reduced
29 CFR 1910.333(a)(1): The employer failed to ensure that live parts were deenergized before employees began to work on or near live parts:    a) On or about 6/27/2018 - in the Small Progressive Department at Bay 3, a Maintenance Technician was changing out an energized 277 volt light fixture resulting in exposure to an electrical hazard.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $12934

1910.147 C06 I

Other-than-serious 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) On or about 6/27/2018 - a periodic inspection had not been conducted since 2010 for authorized employees such as Maintenance Technicians and Press Operators performing service and maintenance activities.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CHOICE FABRICATORS, INC.'s full OSHA safety record →