OSHA Inspection: MILLENNIUM STUCCO CO., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MILLENNIUM STUCCO CO., INC. in 944 DOUGLAS PIKE, SMITHFIELD, RI 02917 (NAICS 238140). OSHA activity number 343264222.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Millennium Stucco CO., INC. — free Get an email when a new federal OSHA severe-injury report for Millennium Stucco CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
944 DOUGLAS PIKE
City
SMITHFIELD
State
RI
ZIP
02917
Mailing
64 SPENCER STREET, ROCHESTER, NY 14608
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

7 citations on file for this inspection.

1903.19 C01

Other-than-serious 2 instances 4 exposed
Issued
Feb 25, 2020
Abate by
Mar 30, 2020
Penalty
Initial $319 · Current $319
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  (a) Establishment:  As of December 17, 2019, the employer had not certified to OSHA that the abatement had been completed for Citation 1, Item 2a and Citation 2, Item 1 from inspection number 1326422, issued on 08/27/2018, with a final order date of 12/05/2019.
Recent events (1)
  • — Z (O) $319

1903.19 D01

Other-than-serious 1 instance 4 exposed
Issued
Feb 25, 2020
Abate by
Mar 30, 2020
Penalty
Initial $0 · Current $0
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:  (a) Establishment:  As of December 17, 2019, the employer had not provided the required abatement documentation to OSHA for Citation 1, Item 2a from inspection number 1326422, issued on 08/27/2018, with a final order date of 12/05/2019.
Recent events (1)
  • — Z (O) $0

1926.416 E01

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 27, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  (a) Worksite:  On or about 6/29/2018, the employer did not take worn electrical cords out of service that were being used to power a drill for mixing cement in a five gallon bucket.
Recent events (3)
  • — J (S) $2217
  • — C (S) $2217
  • — Z (S) $2217

1926.451 E04 I

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 27, 2018
Abate by
Sep 6, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.451(e)(4)(i): A stair-rail consisting of a top-rail and a mid-rail was not provided on each side of each scaffold stairway:  (a) Worksite:  On or about 6/29/2018, the employer did not install a stair-rail to the yellow upper level scaffold stairway.
Recent events (3)
  • — J (S) $3880
  • — C (S) $3880
  • — Z (S) $3880

1926.451 F04

Serious Gravity 10 8 instances 4 exposed
Issued
Aug 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired:  (a) Worksite:  On or about 6/29/2018, the employer did not take rotted and split wood scaffold planks out of service that were being used by employees as part of an erected scaffold system.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 2 instances 4 exposed
Issued
Aug 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:   (a) Worksite:  On or about 6/29/2018, the employer did not ensure that employees were protected from falls while working from a scaffold system at a height of approximately fourteen feet above the lower level.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.454 A

Other-than-serious 1 instance 4 exposed
Issued
Aug 27, 2018
Abate by
Oct 12, 2018
Penalty
Initial $311 · Current $311
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  (a) Worksite:  On or about 6/29/2018, the employer did not ensure that employees working from a seven tier scaffold system were properly trained in the hazards associated with this type of work.
Recent events (3)
  • — J (O) $311
  • — C (O) $311
  • — Z (O) $311

View Millennium Stucco CO., INC.'s full OSHA safety record →