OSHA Inspection: DECATUR RAS, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of DECATUR RAS, LLC in 680 W ELDORADO, DECATUR, IL 62523 (NAICS 562920). OSHA activity number 343267860.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Decatur RAS, LLC for free Get an email when a new federal OSHA severe-injury report for Decatur RAS, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DECATUR RAS, LLC
Site address
680 W ELDORADO
City
DECATUR
State
IL
ZIP
62523
Mailing
680 W ELDORADO, DECATUR, IL 62523
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562920
Employees
9
Ownership type
Private (A)

4 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 17, 2018
Abate by
Oct 17, 2018
Penalty
Initial $2,217 · Current $1,552 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition:    On or about May 22, 2018, employees working in the West Building were exposed to trip and fall hazards from roofing materials piled in the walking-working surfaces by the sort conveyor.
Recent events (2)
  • · I (S) $1552
  • · Z (S) $2217

1910.212 A01

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 17, 2018
Penalty
Initial $2,217 · Current $1,552 Reduced
29 CFR 1910.212(a)(1): The employer did not ensure one or more methods of machine guarding was provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about May 22, 2018, employees working at the sort conveyor in the West Building were exposed to caught-in hazards when ingoing nip points were not guarded in the following instances:     a.) Employees using the stairs to access the elevated work platform were exposed to caught-in hazards when an in-going nip point between the material conveyor and drum was not guarded.    b.) Employees standing at the control box were exposed to caught-in hazards when an in-going nip point between the material conveyor and drum was not guarded.
Recent events (2)
  • · I (S) $1552
  • · Z (S) $2217

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 17, 2018
Abate by
Oct 17, 2018
Penalty
Initial $2,217 · Current $1,552 Reduced
29 CFR 1910.303(b)(2): The employer did not ensure listed or labeled electrical equipment was used or installed in accordance with instructions included in the listing or labeling.    On or about June 8, 2018, employees working in the Truck Shop Building were exposed to electrical hazards from a relocatable electrical power tap used for powering overhead lights. The relocatable power tap was not connected to a permanently installed branch circuit receptacle outlet and was connected in series to another extension cord.
Recent events (2)
  • · I (S) $1552
  • · Z (S) $2217

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 17, 2018
Abate by
Oct 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about June 8, 2018, employees were exposed to electrical hazards while working in the Truck Shop Building and flexible cords were used in lieu of fixed wiring for overhead lights.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343267860.