CHANTILLY, VA ·
OSHA Inspection: SMITHSONIAN INSTITUTION NATIONAL AIR AND SPACE MUSEUM
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SMITHSONIAN INSTITUTION NATIONAL AIR AND SPACE MUSEUM in 14390AIR AND SPACE MUSEUM PKWY MRC 326, CHANTILLY, VA 20151 (NAICS 712110). OSHA activity number 343268363.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 14390AIR AND SPACE MUSEUM PKWY MRC 326
- City
- CHANTILLY
- State
- VA
- ZIP
- 20151
- Mailing
- 14390AIR AND SPACE MUSEUM PKWY MRC 326, CHANTILLY, VA 20151
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 712110
- Employees
- 250
- Ownership type
- Federal government (D)
Citations
2 citations on file for this inspection.
1910.213 I01
- Issued
- Oct 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of band saw(s) were not enclosed or guarded: On or about 06-25-2018 and times prior thereto, located at the Smithsonian National Air & Space Museum, 14390 Air and Space Museum Parkway. Chantilly, VA 20151, Condition: Employee(s) were exposed to unguarded unused portions of a DoALL Contour-Matic 36 inch vertical band saw blade located in the Restoration Shop. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $0
1910.305 A02 X
- Issued
- Oct 24, 2018
- Abate by
- Nov 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: On or about 06-25-2018 and times prior thereto, located at the Smithsonian National Air & Space Museum, 14390 Air and Space Museum Parkway. Chantilly, VA 20151, Condition: Employee(s) were exposed to electrical hazards temporary electrical cords running through holes in the metal deck plate openings going into the subfloor electrical/utility trough. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.