Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DEKAT CONSTRUCTION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DEKAT CONSTRUCTION, INC. in 142-144 MATHER STREET, SYRACUSE, NY 13203 (NAICS 238160). OSHA activity number 343268975.

Watch Dekat Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Dekat Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
142-144 MATHER STREET
City
SYRACUSE
State
NY
ZIP
13203
Mailing
1910 WHITESBORO STREET, UTICA, NY 13502
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2217.00 · Current $2217.00
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a) On or about 6/29/2018, 142-144 Mather Street:  An employee performing ground work was not wearing a hard hat while roofing work was being conducted above him.
Recent events (1)
  • — Z (S) $2217

1926.404 B01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1663.00 · Current $1663.00
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:  a) On or about 6/29/2018, 142-144 Mather Street:  An employee was utilizing a Makita circular saw energized through an extension cord.  No Ground Fault Circuit Interrupter (GFCI) was in use.    Abatement certification is required for this item.
Recent events (1)
  • — Z (S) $1663

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $3880.00 · Current $3880.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) On or about 6/29/2018, 142-144 Mather Street:  Employees performing roofing work on a two family residence with an eave to ground height of over 20 feet with a roof pitch of approximately 10:12, were not utilizing any fall protection.  This exposed employees to falls of over 20 feet from the eaves and over 26 feet from the peak.
Recent events (1)
  • — Z (S) $3880

1926.503 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $2772.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) On or about 6/29/2018, 142-144 Mather Street:  Employees performing roofing work on a two family residence with an eave to ground height of over 20 feet with a roof pitch of approximately 10:12, were not provided with training regarding the proper use of personal fall arrest systems.  Including, but not limited to the proper installation of anchorages, donning and doffing of harnesses, maintenance of ropes, use of rope grabs, and fall protection limitations.     Abatement certification is required for this item.
Recent events (1)
  • — Z (S) $2772

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $2772.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On or about 6/29/2018, 142-144 Mather Street:  Employees performing roofing work on a two family residence with an eave to ground height of over 20 feet were accessing the roof utilizing a portable extension ladder which did not extend three feet past the eave of the roof.   Abatement certification is required for this item.
Recent events (1)
  • — Z (S) $2772

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343268975.