CLIFTON HEIGHTS, PA —
OSHA Inspection: S.R. ROSATI, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of S.R. ROSATI, INC. in 201 EAST MADISON AVENUE, CLIFTON HEIGHTS, PA 19018 (NAICS 311520). OSHA activity number 343269650.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S.R. ROSATI, INC.
- Site address
- 201 EAST MADISON AVENUE
- City
- CLIFTON HEIGHTS
- State
- PA
- ZIP
- 19018
- Mailing
- 201 EAST MADISON AVENUE, CLIFTON HEIGHTS, PA 19018
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311520
- Employees
- 26
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.28 B01 I A
- Issued
- Oct 3, 2018
- Penalty
- Initial $9,054 · Current $5,885 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i)(A): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by Guardrail systems: a. Rear of the Second Floor, Loft - The employer did not ensure that employees working on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by guardrails. Employees were exposed to a fall hazard of approximately 14 feet, 9 inches onto the ground. Observed On or About May 31, 2018
Recent events (2)
- — I (S) $5885.1
- — Z (S) $9054
1910.219 C02 I
- Issued
- Oct 3, 2018
- Abate by
- Oct 23, 2018
- Penalty
- Initial $5,174 · Current $3,363 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a. Production Area, Winsmith Maximizer motor ice pump - The employer did not provide machine guarding to a horizontal rotating shaft to protect employees from the hazards created by rotating parts. Observed On or About 05/31/18
Recent events (2)
- — I (S) $3363.1
- — Z (S) $5174
1910.219 H01
- Issued
- Oct 3, 2018
- Abate by
- Nov 6, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(h)(1): Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s): a. Production - The employer did not guard the projecting head setscrews located on a horizontal shafts on two ice pump motors, thus exposing employees to a caught-in hazard. Observed On or About May 31, 2018
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Oct 3, 2018
- Abate by
- Oct 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a. First Floor - The employer did not keep a compressed gas cylinder of oxygen separate from several propane cylinders. The cylinder was not stored a minimum of 20 feet from the flammable gas, thereby exposing employees to a fire or explosion hazard. Observed On or About 05/31/18
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- Oct 3, 2018
- Abate by
- Oct 23, 2018
- Penalty
- Initial $3,880 · Current $2,522 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment: a. Production Area, along the wall - The employer did not cover unused openings inside a circuit breaker box. Observed On or About 05/31/18
Recent events (2)
- — I (S) $2522
- — Z (S) $3880
1910.305 G01 IV B
- Issued
- Oct 3, 2018
- Abate by
- Oct 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used to run through holes in walls, ceilings, or floors; a. Production, Along the wall, Robopac Machine - The employer ran a flexible cord from a electrical box through the suspended ceiling to the stacking box. Observed On or About 05/31/18
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Oct 3, 2018
- Abate by
- Oct 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a. Production Area - The employer did not provide a a flexible cord hanging from the ceiling with strain relief. Observed On or About 05/31/18
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Oct 3, 2018
- Abate by
- Oct 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. Production Area - The 120 V power cord for the conveyor belt equipment was plugged into a flexible extension cord that was hanging from the ceiling. Observed On or About May 31, 2018
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Oct 3, 2018
- Abate by
- Oct 23, 2018
- Penalty
- Initial $3,880 · Current $2,522 Reduced
00402150C136X100
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: a. Production Area - The employer did not develop and implement a written hazard communication program. Employees regularly worked with Citric Acid Anhydrous Fine Granular 51N, Acetone, Oxygen Compressed Gas, and liquid Propane. Observed On or About 05/31/18
Recent events (2)
- — I (S) $2522
- — Z (S) $3880
1910.1200 F06 II
- Issued
- Oct 3, 2018
- Abate by
- Oct 23, 2018
- Penalty
- Initial $0 · Current $0
C136
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: a. Production Area - The employer did not ensure that a large container that contained Citric Acid Anhydrous was labeled with the product identifier or the general information regarding the hazards of Citric Acid Anhydrous Fine Granular 51N. This chemical can cause eye and skin irritation. Observed On or About 05/31/18
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K06
- Issued
- Oct 3, 2018
- Abate by
- Oct 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a. Production Area - The employer did not provide to an employee who voluntary wore a HDX N95 (TC-84A-5411) filtering facepiece (dust mask) with the basic advisory information on respirators, as presented in Appendix D. Observed On or About 05/31/18
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 F02
- Issued
- Oct 3, 2018
- Abate by
- Oct 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a. Production, Wall - The employer did not legibly mark or label two electrical disconnect boxes for the equipment to indicate the purpose. Observed On or About May 31, 2018
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at S.R. Rosati, INC.
View S.R. Rosati, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311520)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343269650.