Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COUTU AUTO SALES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COUTU AUTO SALES, INC. in 1535 WEST MAIN STREET, WILLIMANTIC, CT 06226 (NAICS 423140). OSHA activity number 343272282.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coutu Auto Sales, INC. — free Get an email when a new federal OSHA severe-injury report for Coutu Auto Sales, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1535 WEST MAIN STREET
City
WILLIMANTIC
State
CT
ZIP
06226
Mailing
1535 WEST MAIN STREET, WILLIMANTIC, CT 06226
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423140
Employees
8
Ownership type
A

7 citations on file for this inspection.

1910.178 L06

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 3, 2018
Abate by
Sep 20, 2018
Penalty
Initial $2,772 · Current $1,386 Reduced
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):   A.  On or about July 3, 2018, Facility:  The employer had not certified that each powered industrial truck operator had been provided training and evaluation on vehicle operation.  Employees operated three Yale forklift vehicles.
Recent events (2)
  • — I (S) $1386
  • — Z (S) $2772

1910.303 B01 IV

Serious Gravity 1 1 instance 6 exposed
Issued
Aug 3, 2018
Abate by
Sep 20, 2018
Penalty
Initial $1,663 · Current $832 Reduced
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation:  A.  On or about July 3, 2018, Cooling Shack:  An orange flexible extension cord used in series to power a Panasonic air conditioner, showed visible signs of damage in that the cord was wrapped in four locations with black electrical tape.  The electrical tape would not provide the same insulative properties as the original undamaged insulation.
Recent events (2)
  • — I (S) $831.5
  • — Z (S) $1663

1910.305 G01 IV B

Serious Gravity 1 1 instance 6 exposed
Issued
Aug 3, 2018
Abate by
Sep 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:   A.  On or about July 3, 2018, Cooling Shack:  A green flexible extension cord with a three-way splitter was run through an air vent in the cooling shack to provide power to a Panasonic CW-82JS12X6U room air conditioner.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV D

Serious Gravity 1 1 instance 6 exposed
Issued
Aug 3, 2018
Abate by
Sep 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces:    A.  On or about July 3, 2018, Cooling Shack:  A green flexible extension cord with a three-way splitter, used to power a Panasonic air conditioner unit, Model CW-85JS12X6U, was attached to the building surface inside the shack.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 F01 VIII

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 3, 2018
Abate by
Sep 20, 2018
Penalty
Initial $1,663 · Current $832 Reduced
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD."   A.  On or about July 3, 2018, Service Garage:  A 20A circuit breaker at position 12 in the General Electric breaker panel was used to turn on and off the lights in the area.  The breaker was not listed and marked "SWD" for Switch Duty.
Recent events (2)
  • — I (S) $831.5
  • — Z (S) $1663

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 3, 2018
Abate by
Sep 20, 2018
Penalty
Initial $2,772 · Current $1,386 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   A.  On or about July 3, 2018, Service Garage:  An unused opening at breaker position 12 in the General Electric breaker panel was not covered by a breaker or blank.  The panel was energized at the time of the inspection and the door was open, exposing employees to electric shock hazards.
Recent events (2)
  • — I (S) $1386
  • — Z (S) $2772

1910.1200 E01

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 3, 2018
Abate by
Nov 2, 2018
Penalty
Initial $2,217 · Current $1,109 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  A.  On or about July 3, 2018, Facility:  The employer had not developed or implemented a written hazard communication program which included information on container labeling, safety data sheets and training to inform employees of the hazards of chemicals with which they worked, including flammable B'laster PB penetrating catalyst and propane.
Recent events (2)
  • — I (S) $1108.5
  • — Z (S) $2217

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343272282.