Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MELANSON COMPANY, INC., THE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MELANSON COMPANY, INC., THE in 75 PLUNKETT STREET, PITTSFIELD, MA 01201 (NAICS 238160). OSHA activity number 343275848.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Melanson Company, INC., the — free Get an email when a new federal OSHA severe-injury report for Melanson Company, INC., the is published. One employer, no account, unsubscribe in one click.
Site address
75 PLUNKETT STREET
City
PITTSFIELD
State
MA
ZIP
01201
Mailing
PO BOX 525, KEENE, NH 03431
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
28
Ownership type
A

3 citations on file for this inspection.

1926.501 B04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 4, 2018
Abate by
Oct 19, 2018
Penalty
Initial $9,054 · Current $4,527 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.    (a) Site: Access point from the third Story Roof Repair Project to the attic at 75 Plunkett Street, Pittsfield, MA 01201 on 7/5/2018 employees worked in the vicinity the access point/hole which was more than six feet (1.8 m) above the attic floor and were not protected by personal fall arrest systems, covers, or guardrail systems erected around the hole.
Recent events (2)
  • — I (S) $4527
  • — Z (S) $9054

1926.1053 B01

Other-than-serious 1 instance 5 exposed
Issued
Sep 4, 2018
Abate by
Oct 19, 2018
Penalty
Initial $9,054 · Current $0 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    (a) Site: Access point from the attic to the third Story Roof Repair Project at 75 Plunkett Street, Pittsfield, MA 01201 on 7/5/2018 the side rails for the portable ladder used for access to the roof did not extend at least 3 feet (.9 m) above the roof's landing surface.
Recent events (2)
  • — I (O) $0
  • — Z (S) $9054

1926.503 C03

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 4, 2018
Abate by
Oct 19, 2018
Penalty
Initial $18,108 · Current $4,527 Reduced
29 CFR 1926.503(c)(3):     When the employer has reason to believe that any affected employee who has already been trained does not have the understanding and skill required by paragraph (a) of this section, the employer did not  retrain each such employee.    a) Site: Third Story Roof repair project at 75 Plunkett Street, Pittsfield, MA 01201 on 7/5/2018 the safety monitor was observed on the roof using a shovel to fill a debris container and was observed in multiple instances facing away from the exposed employees in order to otherwise assist with roof repair work.
Recent events (2)
  • — I (S) $4527
  • — Z (R) $18108

View Melanson Company, INC., the's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343275848.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.