OSHA Inspection: UNITED CONTRACTORS MIDWEST, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of UNITED CONTRACTORS MIDWEST, INC. in 1058 950TH STREET, ELKHART, IL 62634 (NAICS 237110). OSHA activity number 343278545.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Contractors Midwest, INC. — free Get an email when a new federal OSHA severe-injury report for United Contractors Midwest, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1058 950TH STREET
City
ELKHART
State
IL
ZIP
62634
Mailing
3151 ROBBINS RD, SPRINGFIELD, IL 62704
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
445
Ownership type
A

2 citations on file for this inspection.

1926.416 A03

Serious Gravity 10 2 instances 4 exposed
Issued
Dec 17, 2018
Abate by
Feb 8, 2019
Penalty
Initial $12,934 · Current $12,934
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit:   On or about June 30, 2018, employees performing roadway paving activities were exposed to electric shock hazards:   a. The employer did not ascertain whether any of the equipment used would contact the energized overhead power lines.   b. The employer did not train employees of the hazards involved and the protective measures  that were to be taken.
Recent events (2)
  • — I (S) $12934
  • — Z (S) $12934

1926.600 A06 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 17, 2018
Abate by
Jan 17, 2019
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1926.600(a)(6)(i):  For lines rated 50kV or below, a minimum of 10 feet was not maintained between the energized line and the equipment:     On or about June 30, 2018, employees performing roadway paving operations were exposed to electric shock hazards and the employer did not ensure that the equipment being used was at least 10 feet from the energized overhead power line.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12934

View United Contractors Midwest, INC.'s full OSHA safety record →