AUSTIN, TX —
OSHA Inspection: LEHNE CONSTRUCTION, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of LEHNE CONSTRUCTION, INC. in 416 WEST 11TH STREET, AUSTIN, TX 78701 (NAICS 238110). OSHA activity number 343281358.
Where did this inspection happen?
- Establishment
- LEHNE CONSTRUCTION, INC.
- Site address
- 416 WEST 11TH STREET
- City
- AUSTIN
- State
- TX
- ZIP
- 78701
- Mailing
- 22111 HWY 71, STE 101, SPICEWOOD, TX 78669
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 B02
- Issued
- Abate by
- Penalty
- Initial $6467.00 · Current $3880.00 Reduced
General-duty citation text
29 CFR 1926.651(b)(2): Utility companies or owners were not contacted within established or customary local response times, advised of the proposed work, and asked to establish the location of the utility underground installations prior to the start of actual excavation. When utility companies or owners cannot respond to a request to locate underground utility installations within 24 hours (unless a longer period is required by state or local law), or cannot establish the exact location of these installations, the employer may proceed, provided the employer does so with caution, and provided detection equipment or other acceptable means to locate utility installations are used. On or about 25 April 2018, and at times prior thereto, a mini-excavator was digging a hand-hole for electrical conduit installation when the bucket ruptured a 2-inch gas line, exposing the operator and those nearby to an explosion hazard. The service provider for the gas line was not contacted prior to the actual excavation at the site of the gas line area.
Recent events (2)
- — I (S) $3880.2
- — Z (S) $6467
1926.651 B03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(b)(3): When excavation operations approach the estimated location of underground installations, the exact location of the installations were not determined by safe and acceptable means. On or about 25 April 2018, and at times prior thereto, a mini-excavator was digging a hand-hole for electrical conduit installation when the bucket ruptured a 2-inch gas line, exposing the operator and those nearby to an explosion hazard. Line locates were not conducted by the service provider prior to excavating in the area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238110)
MARIANNA, FL—2026-07-16 00:00:00
BRANNON BROTHERS CONSTRUCTION, LLC
NAMPA, ID—2026-07-15 00:00:00
ICON BUILDING SOLUTIONS LLC
DULUTH, MN—2026-07-14 00:00:00
111602 - JMF CONSTRUCTION INC
REDDING, CA—2026-07-14 00:00:00
EMERGENT CONSTRUCTION, INC.
CLEVELAND, OH—2026-07-14 00:00:00
MIENCORP MASONRY
More inspections in TX
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16 00:00:00
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15 00:00:00
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15 00:00:00
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15 00:00:00
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343281358.