Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LEHNE CONSTRUCTION, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of LEHNE CONSTRUCTION, INC. in 416 WEST 11TH STREET, AUSTIN, TX 78701 (NAICS 238110). OSHA activity number 343281358.

Watch Lehne Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Lehne Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
416 WEST 11TH STREET
City
AUSTIN
State
TX
ZIP
78701
Mailing
22111 HWY 71, STE 101, SPICEWOOD, TX 78669
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.651 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6467.00 · Current $3880.00 Reduced
29 CFR 1926.651(b)(2): Utility companies or owners were not contacted within established or customary local response times, advised of the proposed work, and asked to establish the location of the utility underground installations prior to the start of actual excavation. When utility companies or owners cannot respond to a request to locate underground utility installations within 24 hours (unless a longer period is required by state or local law), or cannot establish the exact location of these installations, the employer may proceed, provided the employer does so with caution, and provided detection equipment or other acceptable means to locate utility installations are used.  On or about 25 April 2018, and at times prior thereto, a mini-excavator was digging a hand-hole for electrical conduit installation when the bucket ruptured a 2-inch gas line, exposing the operator and those nearby to an explosion hazard. The service provider for the gas line was not contacted prior to the actual excavation at the site of the gas line area.
Recent events (2)
  • — I (S) $3880.2
  • — Z (S) $6467

1926.651 B03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(b)(3): When excavation operations approach the estimated location of underground installations, the exact location of the installations were not determined by safe and acceptable means.  On or about 25 April 2018, and at times prior thereto, a mini-excavator was digging a hand-hole for electrical conduit installation when the bucket ruptured a 2-inch gas line, exposing the operator and those nearby to an explosion hazard. Line locates were not conducted by the service provider prior to excavating in the area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343281358.