Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOEL GONZALEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOEL GONZALEZ in 917 AMBER STREET, PRINCETON, TX 75407 (NAICS 238160). OSHA activity number 343281531.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Joel Gonzalez — free Get an email when a new federal OSHA severe-injury report for Joel Gonzalez is published. One employer, no account, unsubscribe in one click.
Establishment
JOEL GONZALEZ
Site address
917 AMBER STREET
City
PRINCETON
State
TX
ZIP
75407
Mailing
9811 JENNIE LEE LANE, DALLAS, TX 75227
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 13, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):      a) On July 5, 2018 an employee was observed roofing a house being built at 917 Amber Street, Princeton, TX approximately 9 feet, 6 inches or more above the debris strewn ground below and was not protected from a fall hazard by using either guardrail systems, safety net systems, or personal fall arrest systems.
Recent events (1)
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 13, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed; the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:  a) On July 5, 2018 an employee was observed using an extension ladder at a worksite located at 917 Amber Street, Princeton, TX which was only approximately 6 inches above the upper landing thereby exposing the employee using it to a fall hazard of approximately 9 feet, 6 inches to the debris strewn ground below.
Recent events (1)
  • — Z (S) $3880

View Joel Gonzalez's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343281531.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.