BROOKLYN, NY —
OSHA Inspection: SLC CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SLC CONSTRUCTION INC. in 4618 7TH AVENUE, BROOKLYN, NY 11220 (NAICS 236118). OSHA activity number 343286241.
Where did this inspection happen?
- Establishment
- SLC CONSTRUCTION INC.
- Site address
- 4618 7TH AVENUE
- City
- BROOKLYN
- State
- NY
- ZIP
- 11220
- Mailing
- 790 QUEENS BLVD, FLUSHING, NY 11373
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.403 I02 I
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $2808.00 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. Location: 4618 7th Ave 2nd floor On or about: July 10, 2018 a) Workers walking and working next to energized breaker panel that was not equipped with a cover while conducting remodeling operations.
Recent events (2)
- — I (S) $2808
- — Z (S) $3880
1926.405 B02
- Issued
- Abate by
- Penalty
- Initial $2772.00 · Current $1696.00 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: Location: 4618 7th Ave 2nd floor On or about: July 10, 2018 a) Energized outlet boxes throughout entire site were not provided with a cover. Energized wires were exposed.
Recent events (2)
- — I (S) $1696
- — Z (S) $2772
1926.1052 B01
- Issued
- Abate by
- Penalty
- Initial $2772.00 · Current $1696.00 Reduced
General-duty citation text
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan. Location: 4618 7th Ave 2nd floor On or about: July 10, 2018 a) Employees onsite used stairs that were not filled in with concrete or any other material that was secured in place.
Recent events (2)
- — I (S) $1696
- — Z (S) $2772
1926.1052 C01 I
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $2800.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS)Note: 29 CFR 1926.1052(c)(7) applies when the top edge of a stairrail system also serves as a handrail. Location: 4618 7th Ave On or about: July 10, 2018 a) Employees used stairs that were not equipped with at least one hand rail to access the 2nd and 3rd floors of site.
Recent events (2)
- — I (S) $2800
- — Z (S) $3880
More inspections in this industry (NAICS 236118)
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
VANCOUVER, WA—2026-07-08
WA317991978 - DLS CONTRACTING INC
NEWPORT BEACH, CA—2026-07-08
DRAKE SMITH CONSTRUCTION
BRIDGEVILLE, PA—2026-07-08
EXTREME DECKS
COLUMBUS, OH—2026-07-07
QUALITY BUILDS OHIO LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source