HIGH SPRINGS, FL —
OSHA Inspection: CONVERTIBLE BUILDERS LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of CONVERTIBLE BUILDERS LLC in 25845 W US HIGHWAY 27, HIGH SPRINGS, FL 32643 (NAICS 336111). OSHA activity number 343288536.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONVERTIBLE BUILDERS LLC
- Site address
- 25845 W US HIGHWAY 27
- City
- HIGH SPRINGS
- State
- FL
- ZIP
- 32643
- Mailing
- 25845 W US HIGHWAY 27, HIGH SPRINGS, FL 32643
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336111
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.305 G02 III
- Issued
- Aug 29, 2018
- Abate by
- Sep 25, 2018
- Penalty
- Initial $1,663 · Current $832 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) On or about July 10, 2018, in the paint and mechanical/fabrication area, the employer failed to ensure that an effective strain release was attached to the plug of the flexible electrical cord of the "Central Machinery" belt and 9" sander model T6852. b) On or about July 10, 2018, in the paint and mechanical/fabrication area, the employer failed to ensure that an effective strain release was attached to the flexible electrical cord at the point of entry into the metal body of the "Central Machinery" belt and 9" sander model T6852.
Recent events (2)
- — I (S) $831.5
- — Z (S) $1663
1910.303 G01
- Issued
- Aug 29, 2018
- Abate by
- Oct 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about July 10, 2018, in the paint and mechanical/fabrication area, the employer failed to ensure that the space in front of electrical panels was free of obstructions to permit ready access. Tool carts and racks with tubing and other materials were stored in front of the lights panel and circuit #5 switch.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Aug 29, 2018
- Abate by
- Oct 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about July 10, 2018, the employer failed to develop and implement a written Hazard Communication Program for the protection of the employees that use hazardous chemicals, including but not limited to #3416 Economy Lacquer Thinner and Ben's BPS-009 flammable paints.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 336111)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343288536.