COVINGTON, GA —
OSHA Inspection: CONTRACT PACKAGING, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CONTRACT PACKAGING, INC. in 13100 INDEPENDENCE DRIVE, COVINGTON, GA 30014 (NAICS 325320). OSHA activity number 343288791.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONTRACT PACKAGING, INC.
- Site address
- 13100 INDEPENDENCE DRIVE
- City
- COVINGTON
- State
- GA
- ZIP
- 30014
- Mailing
- 13100 INDEPENDENCE DRIVE, COVINGTON, GA 30014
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325320
- Employees
- 127
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.219 F03
- Issued
- Dec 21, 2018
- Abate by
- Jan 11, 2019
- Penalty
- Initial $4,240 · Current $2,544 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: On or about July 23, 2018 employees were exposed to hazards from an inadequately guarded chain and sprocket under the line 4 accumulator table where the wire mesh guarding had pulled aware from the frame enclosure leaving a triangular opening measuring 5 inches along the vertical edge and 8.5 inches along the horizontal edge.
Recent events (2)
- — I (S) $2544
- — Z (S) $4240
1910.303 G02 I
- Issued
- Dec 21, 2018
- Penalty
- Initial $7,068 · Current $4,241 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures: On or about July 11, 2017 employees working on bottling line 3 were exposed to electrical hazards where the cover plate on the accumulator table snap switch was broken exposing employees to energized conductors.
Recent events (2)
- — I (S) $4240.8
- — Z (S) $7068
1910.305 G02 III
- Issued
- Dec 21, 2018
- Penalty
- Initial $7,068 · Current $4,241 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about July 11, 2018 employees were exposed to hazards associated with improper use of electrical equipment where the employer used extension cords as a substitute for fixed wiring to facilitate the connection of cord and plug connected equipment to branch circuit receptacles. a. Strain relief was not provided to insulated, electrical conductors entering a pull box the "Harland" Sirius labeling machine on bottling line 3 and the conduit through which the conductors ran was taped to the pull box where the strain relief failed. b. Strain relief was not provided to insulated, electrical conductors entering a pull box attached to a 180 volt electric motor on or adjacent to the "Harland" Sirius labeling machine on bottling line 3.
Recent events (2)
- — I (S) $4240.8
- — Z (S) $7068
1910.134 E01
- Issued
- Dec 21, 2018
- Abate by
- Jan 11, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about July 11, 2018 employees working in the Sevin Dust bottling area were exposed to hazards associated with the use of filtering facepiece respirators where the employer required employees at the filling stations to wear "3M" model 8511, N95 respirators but did not provide the affected employees with a medical evaluation prior to being fit tested or required to use the respirator.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K01 V
- Issued
- Dec 21, 2018
- Abate by
- Jan 11, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(1)(v): The employer did not ensure that each user could demonstrate knowledge of the procedures for respirator maintenance and storage: On or about July 11, 2018 employees working in the Sevin Dust bottling area were exposed to hazards associated with the use of filtering facepiece respirators where the employer required employees at the filling stations to wear "3M" model 8511, N95 respirators but did not provide the affected employees with training to include maintenance and care of respirators.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Dec 21, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about July 11, 2018 employees were exposed to electrical hazards where the employer used 4 inch by 4 inch electrical boxes as pendant receptacles not secured to the building structure on lines 1 through 4 to provide power to equipment including, but not limited to, floor fans, accumulator tables, labeling machines and capping machines; a. a four inch by four inch electrical box was used as a pendant receptacle to power a tape machine on line 2 b. a four inch by four inch electrical box was used as a pendant receptacle to power an accumulator table on line 2 c. a four inch by four inch electrical box was used as a pendant receptacle to power a Maxx Air Pro fan on line 3 d. a four inch by four inch electrical box was used as a pendant receptacle to power a fan on line 4 e. a four inch by four inch electrical box was used as a pendant receptacle to power an accumulator table and a "NITA" model XP200T labeling machine on line 4 f. a four inch by four inch electrical box was used as a pendant receptacle to power a capping machine and fan on line four
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Dec 21, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about July 11, 2018 employees were exposed to hazards associated with improper use of electrical equipment where the employer used extension cords as a substitute for fixed wiring to facilitate the connection of cord and plug connected equipment to branch circuit receptacles. a. An extension cord was used to connect the "Sure Kap" cap tightening machine on line 2 to a receptacle in a 4 inch by 4 inch box mounted to a vertical beam. b. An extension cord was used to connect the "Sure Kap" cap tightening machine on line 3 to a receptacle in a 4 inch by 4 inch box mounted to a vertical beam.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV D
- Issued
- Dec 21, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and/or cables were used where attached to building surfaces: On or about July 11, 2018 employees were exposed to hazards associated with improper use of electrical equipment where flexible cords used to provide power to cord and plug connected bottling equipment was attached to building surfaces using packaging or similar tape. a. On bottling line 3 where an extension cord was used to connect the "Sure Kap" cap tightening machine to a receptacle box mounted to a vertical beam, plastic material was used to secure the extension cord to the receptacle box and the conveyor frame. b. On bottling line 3 plastic material was used to secure the cord and plug of the accumulator table to a receptacle box mounted to a vertical beam.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Dec 21, 2018
- Abate by
- Jan 11, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about June 11, 2018 temporary employees working with chemicals including, but not limited to, Gardentech Sevin 5 Ready-To-Use 5% Dust, Gardentech Sevin Ready-To-Use Bug Killer, and F6570 Master Insecticide were not provided effective chemical hazard communication program training where the employees only received general hazard communication information from their temporary agency prior to work at the host site.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Contract Packaging, INC.
View Contract Packaging, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325320)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343288791.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.