WASHINGTON, DC —
OSHA Inspection: LAMY ENTERPRISES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LAMY ENTERPRISES in 4937 NACARTHUR BLVD NW, WASHINGTON, DC 20016 (NAICS 238130). OSHA activity number 343290870.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LAMY ENTERPRISES
- Site address
- 4937 NACARTHUR BLVD NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 4937 MACARTHUR BLVD, NW, WASHINGTON, DC 20007
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.403 B02
- Issued
- Oct 31, 2018
- Abate by
- Nov 8, 2018
- Penalty
- Initial $3,880 · Current $2,522 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about July 10, 2018; second floor; employee was using a surge/power strip to provide power to equipment such as but not limited to circular saws and compressors. b) On or about July 10, 2018; second floor; employee were using energized electrical boxes that were not properly mounted as they were designed. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2522
- — Z (S) $3880
1926.405 B02
- Issued
- Oct 31, 2018
- Abate by
- Nov 8, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) On or about July 10, 2018; second floor area; employees had equipment such as but not limited to the air compressor plugged into electrical boxes that were missing faceplates exposing them to a shock hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Oct 31, 2018
- Abate by
- Nov 8, 2018
- Penalty
- Initial $3,880 · Current $2,522 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about July 10, 2018; second floor area; employees were working near floor openings such as but not limited to the stair opening that was not guarded exposing them to an estimated 10-foot fall to the lower level. b) On or about July 10, 2018; roof area; employees were working near unguarded wall openings exposing them to an estimated 27-foot fall to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2522
- — Z (S) $3880
1926.502 D11
- Issued
- Oct 31, 2018
- Abate by
- Nov 8, 2018
- Penalty
- Initial $3,880 · Current $2,522 Reduced
General-duty citation text
29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded: a) On or about July 10, 2018; third floor; employees that were using full body harness, while working on the porch area, had tied thier lines around the central beam located on the third floor exposing line to being abraded while it moved around the beam. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2522
- — Z (S) $3880
1926.503 B01
- Issued
- Oct 31, 2018
- Abate by
- Nov 13, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written certification record that contains the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer and when the employer relies on training conducted by another employer the certification record needs to indicate the date the employer determined the prior training was adequate rather than the date of actual training. a) On or about July 10, 2018; porch area; the employer had not verified the fall protection training to employees that were exposed to fall hazards 6-feet and greater as well as methods to abate or protect themselves while conducting their assigned duties. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Lamy Enterprises
View Lamy Enterprises's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343290870.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.