COLORADO SPRINGS, CO —
OSHA Inspection: HIGH WEST SIDING AND WINDOWS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HIGH WEST SIDING AND WINDOWS, INC. in 20 MOUNTAIN VIEW LANE STE F, COLORADO SPRINGS, CO 80907 (NAICS 238170). OSHA activity number 343291779.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HIGH WEST SIDING AND WINDOWS, INC.
- Site address
- 20 MOUNTAIN VIEW LANE STE F
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80907
- Mailing
- 20 MOUNTAIN VIEW LANE, COLORADO SPRINGS, CO 80907
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 10
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.25 C02
- Issued
- Jul 25, 2018
- Penalty
- Initial $1,663 · Current $831 Reduced
General-duty citation text
29 CFR 1910.25(c)(2): The employer did not ensure standard stairs have a maximum riser height of 9.5 inches (24 cm): a) On or about July 10, 2018, and at times prior, employees in the warehouse were exposed to trip and fall hazards where the rise of the top step of the stairway leading to the upper storage area was greater than 9.5 inches.
Recent events (2)
- — I (S) $831
- — Z (S) $1663
1910.25 C03
- Issued
- Jul 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.25(c)(3): The employer did not ensure standard stairs have a minimum tread depth of 9.5 inches (24 cm): a) On or about July 10, 2018, and at times prior, employees in the warehouse were exposed to trip and fall hazards where the tread run of the top step of the stairway leading to the upper storage area was less than 9.5 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.28 B11 II
- Issued
- Jul 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails as required in Table D-2 of this standard: a) On or about July 10, 2018, and at times prior, employees in the warehouse were exposed to trip and fall hazards where the stairway leading to the upper storage area did not have a handrail.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.28 B01 I
- Issued
- Jul 25, 2018
- Penalty
- Initial $1,663 · Current $832 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling: a) On or about July 10, 2018, and at times prior, employees in the warehouse were exposed to fall hazards where at the upper storage area the working surface above the stairway opening did not have any fall protection system in place.
Recent events (2)
- — I (S) $832
- — Z (S) $1663
1910.37 A03
- Issued
- Jul 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) On or about July 10, 2018, and at times prior, employees were exposed to fire hazard where the exit route to the rear exit door was not maintained in a clear and unobstructed manner.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E03
- Issued
- Jul 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) On or about July 10, 2018, and at times prior, employees in the warehouse were exposed to fire and burn hazards where the portable fire extinguisher had not been inspected annually and had not been maintained or replaced after expiration.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Jul 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) On or about July 10, 2018, and at times prior, employees in the warehouse area were exposed to electrical hazards where junction boxes underneath the overhead storage area on the west wall did not have covers in place, exposing the live conductors.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238170)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343291779.