Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MMC SPECIALTY ROOFING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MMC SPECIALTY ROOFING INC. in 16 VERNON AVENUE, VERNON, CT 06066 (NAICS 238160). OSHA activity number 343293395.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MMC Specialty Roofing INC. — free Get an email when a new federal OSHA severe-injury report for MMC Specialty Roofing INC. is published. One employer, no account, unsubscribe in one click.
Site address
16 VERNON AVENUE
City
VERNON
State
CT
ZIP
06066
Mailing
50 VALLEY VIEW DRIVE, WESTFIELD, MA 01085
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

3 citations on file for this inspection.

1926.25 A

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 13, 2018
Penalty
Initial $1,829 · Current $915 Reduced
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris were not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:  On or around 07/11/2018 at the 16 Vernon Avenue Re-Roofing Project, employees were working at and near 2x4 lumber with protruding nails sticking upward.
Recent events (2)
  • — I (S) $914.5
  • — Z (S) $1829

1926.502 F01

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 13, 2018
Penalty
Initial $3,049 · Current $1,525 Reduced
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area:  On or about 07/11/2018 at the 16 Vernon Avenue Re-Roofing Project, employees were working from a roof deck using a warning line system that did not enclosed the protection area.
Recent events (2)
  • — I (S) $1524.5
  • — Z (S) $3049

1926.502 F01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 13, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(1)(ii): 29 CFR 1926.502(f)(1)(ii):  When mechanical equipment was being used, the warning line was not erected at least 6 feet (1.8 m) from the roof edge which is parallel to the direction of mechanical equipment operation, and at least 10 feet (3.1 m) from the roof edge which is perpendicular to the direction of mechanical equipment operation.  On or about 07/11/2018 employees were working on the roof deck using a warning line system as fall protection and the warning line system was not 6 and 10 feet from the unguarded roof edges.